PCNEO, a New Proficiency Testing Program for Flow Cytometric Analysis of Plasma Cell Neoplasms From the College of American Pathologists Diagnostic Immunology and Flow Cytometry Committee

Author:

Dorfman David M.1,Devitt Katherine A.2,Cui Wei3,Bashleben Christine4,Naharro Elena C. Frye5,Hedley Benjamin6,Hupp Meghan5,Karlon William J.7,Murphy Claire E.8,Cherian Sindhu9,Olteanu Horatiu10,Seifert Robert P.11,Rosado Flavia N.12,Linden Michael A.5

Affiliation:

1. From the Department of Pathology, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts (Dorfman)

2. The Department of Pathology and Laboratory Medicine, University of Vermont Medical Center, Burlington (Devitt)

3. The Department of Pathology and Laboratory Medicine, University of Kansas Health System, Kansas City (Cui)

4. Laboratory Improvement Programs, Surveys, College of American Pathologists, Northfield, Illinois (Bashleben)

5. The Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis (Naharro, Hupp, Linden)

6. The Department of Pathology and Laboratory Medicine, London Health Sciences Centre, London, Ontario, Canada (Hedley)

7. The Department of Laboratory Medicine, University of California, San Francisco (Karlon)

8. Pathology Consultants, Springfield, Oregon (Murphy)

9. The Department of Laboratory Medicine and Pathology, University of Washington, Seattle (Cherian)

10. The Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota (Olteanu)

11. The Department of Pathology, Immunology and Laboratory Medicine, University of Florida College of Medicine, Gainesville (Seifert)

12. The Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania (Rosado)

Abstract

Context.— In 2018 the College of American Pathologists Diagnostic Immunology and Flow Cytometry Committee designed and implemented a new plasma cell neoplasia flow cytometry proficiency testing program—PCNEO—to allow clinical flow cytometry laboratories to monitor and assess their performance compared with a peer group. Objective.— To report the results from the first 4 years of the PCNEO program. Design.— Program participants were sent 2 sets of challenges per year, each including 1 wet challenge and 2 dry challenges, with associated clinical and laboratory findings. The wet challenges were composed of myeloma cell line specimens (with or without dilution in preserved whole blood) for flow cytometric analysis. The dry (paper) challenges were composed of clinical case summaries and images of flow cytometric test results from various flow cytometry laboratories of committee members. Results.— A total of 116 to 145 laboratories from 17 countries enrolled in the proficiency testing program. For the wet challenges, almost all participants (97%–100%; cumulative, 98.2%) correctly identified the presence of neoplastic plasma cell populations based on flow cytometric analysis of undiluted myeloma cell lines. Slightly fewer participants (89.0%–97.4%; cumulative, 95.2%) correctly identified the presence of neoplastic plasma cell populations based on flow cytometric analysis of diluted myeloma cell lines (10% or 50% dilutions into peripheral blood) intended to better represent a typical clinical sample. There was generally agreement among 80% or more of participants for positive or negative staining for CD38, CD138, CD19, CD20, and surface and cytoplasmic κ and λ light chains. Similarly, 84% to 100% of participants were able to correctly identify the presence of neoplastic plasma cell populations in paper challenges, including the presence of small, neoplastic plasma cell populations (0.01%–5.0% clonal plasma cells), or the presence of nonneoplastic plasma cell populations (correctly identified by 91%–96% of participants). Conclusions.— Participant performance in the new proficiency testing program was excellent overall, with the vast majority of participants able to perform flow cytometric analysis and identify neoplastic plasma cell populations, and to identify small plasma cell clones or expanded populations of reactive plasma cells in dry challenge flow cytometry results. This program will allow laboratories to verify the accuracy of their testing program and test interpretations for the assessment of patients suspected of having a plasma cell neoplasm.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3