Optimal Frequency of Changing Intravenous Administration Sets: Is It Safe to Prolong Use Beyond 72 Hours?

Author:

Raad Issam,Hanna Hend A.,Awad Abeer,Alrahwan Amin,Bivins Carol,Khan Asma,Richardson Deborah,Umphrey Jan L.,Whimbey Estella,Mansour Georganne

Abstract

AbstractObjective:To determine the safety and cost-effectiveness of replacing the intravenous (TV) tubing sets in hospitalized patients at 4- to 7-day intervals instead of every 72 hours.Design:Prospective, randomized study of infusion-related contamination associated with changing IV tubing sets within 3 days versus within 4 to 7 days of placement.Setting:A tertiary university cancer center.Patients and Methods:Cancer patients requiring IV infusion therapy were randomized to have the IV tubing sets replaced within 3 days (280 patients) or within 4 to 7 days of placement (232 patients). Demographic, microbiological, and infusion-related data were collected for all participants. The main outcome measures were infusion- or catheter-related contamination or colonization of IV tubing, determined by quantitative cultures of the infusate, and infusion- or catheter-related bloodstream infection (BSI), determined by quantitative culture of the infusate in association with blood cultures in febrile patients.Results:The two groups were comparable in terms of patient and catheter characteristics and the agents given through the IV tubing. Intent-to-treat analysis demonstrated a higher level of tubing colonization in the 4- to 7-day group versus the 3-day group (median, 145 vs 50 colony-forming units;P=.02). In addition, there were three episodes of possible infusion-related BSIs, all of which occurred in the 4- to 7-day group (P=.09). However, when the 84 patients who received total parenteral nutrition, blood transfusions, or interleukin-2 through the IV tubing were excluded, the two groups had a comparable rate of colonization (0.4% vs 0.5%), with no catheter- or infusion-related BSIs in either group.Conclusion:In patients at low risk for infection from infusion- or catheter-related infection who are not receiving total parenteral nutrition, blood transfusions, or interleukin-2, delaying the replacement of IV tubing up to 7 days may be safe, as well as cost-effective.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Cited by 64 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. S3-Leitlinie Heimenterale und heimparenterale Ernährung der Deutschen Gesellschaft für Ernährungsmedizin (DGEM);Aktuelle Ernährungsmedizin;2024-04

2. Evaluation of infections associated with central venous catheters in ICU;Middle Black Sea Journal of Health Science;2023-08-31

3. Identificación de bacterias presentes en tres soluciones intravenosas en un periodo mayor a 72 horas;Revista Científica de la Facultad de Ciencias Veterinarias;2023-06-18

4. ESPEN practical guideline: Home parenteral nutrition;Clinical Nutrition;2023-03

5. Care of Indwelling Device Insertion Sites;Advanced Monitoring and Procedures for Small Animal Emergency and Critical Care;2023-02-17