Case-Control Study of Surgical Site Infections Associated With Pacemakers and Implantable Cardioverter-Defibrillators

Author:

Marschall Jonas,Hopkins-Broyles Diane,Jones Marilyn,Fraser Victoria J.,Warren David K.

Abstract

Objective.In 2000, the rate of surgical site infections (SSIs) associated with pacemaker and implantable cardioverter-defibrillator (ICD) procedures performed in the cardiothoracic operating rooms of hospital A was 16% (19 of 116 procedures resulted in infections). This study investigates risks for SSI associated with these procedures in the cardiothoracic operating room.Design.Unmatched 1: 3 case-control study performed over a 12-month period among patients who had undergone implantation of a pacemaker and/or ICD. A standardized observation scrutinized infection control practices in the area where the procedures were performed.Setting.The cardiothoracic operating rooms of hospital A, which belongs to a hospital consortium in the midwestern United States.Patients.Patients with SSI were identified as case patients. Control patients were chosen from the group of uninfected patients who had procedures performed during the same period as case patients.Results.A total of 19 SSIs associated with pacemaker and ICD procedures were retrospectively identified among the patients who underwent procedures in these cardiothoracic operating rooms. Culture samples were obtained from 7 patients; 2 yielded coagulase-negativeStaphylococcuson culture, 2 yieldedStaphylococcus aureus, 1 yieldedSerratia marcescens, and 2 showed no growth. In the case-control study, age, race, sex, diabetes mellitus, smoking history, timing of antibiotic therapy, and hair removal did not differ significantly between case patients and control patients. Case patients were more likely to have an abdominal device in place (odds ratio [OR], 5.5 [95% confidence interval {CI}, 1.6-19.3];P= .006) and less likely to have received a new implant (OR 0.3 [95% CI, 0.1-0.8];P= .02) or to have had new leads placed (OR, 0.2 [95% CI, 0.1-0.6];P= .003).Conclusions.Abdominal placement of implanted devices was associated with occurrence of an SSI after pacemaker and/or ICD procedures.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3