Abstract
A micellar thin-layer chromatography method for the quantitative determination and validation of coumarin in Meliloti herba and its ethanolic extracts was developed and validated. For achieving good determination, the mobile phase of 5 x 10-4 mol/L Tween-80 in a mixture propanol-2 – water (5:95 v/v) was used. Densitometric determination was carried out at 275 nm. The calibration curve was linear in the range of 0.1-2.5 μg per band. The proposed method is simple, rapid, precise and accurate; replacing hazardous solvents by greener ones correspond to the modern requirements in “Green chemistry” concepts. The obtained data can be used for the routine analysis of coumarin in medical plant and extracts.
Publisher
Heighten Science Publications Corporation
Reference31 articles.
1. 1. Bruneton J. Pharmacognosie. Phytochimie, Plantes médicinales. 4e éd., EM Inter / Lavoisier Tec & Doc, Paris. 2009; 1-270.
2. 2. Luca SV, Głowniak K, Skalicka-Woźniak K. Coumarins: Analytical and Preparative Techniques. In Encyclopedia of Analytical Chemistry, Online ©2006-2018 John Wiley & Sons, Ltd. 2018.
3. 3. Glowniak K, Widelski J. Coumarins: TLC Analysis. In: Encyclopedia of Chromatography, Third Edition. Jack Cazes Ed., CRC Press 2009; 2850.
4. 4. Waksmundzka-Hajnos M, Hawrył M. Application of TLC in the Isolation and Analysis of Coumarins. In: Thin Layer Chromatography in Phytochemistry. Eds: Waksmundzka-Hajnos M, Sherma J, Kowalska T, CRC Press 2020; 896.
5. 5. Lozhkin AV, Sakanyan EI. Natural coumarins: Methods of isolation and analysis. Pharm Chem J. 2006; 40; 337-346.