Affiliation:
1. *Curtin Corrosion Centre, Western Australian School of Mines: Minerals, Energy and Chemical Engineering, Curtin University, 5 De Laeter Way, Bentley, Perth, Western Australia, Australia 6102.
Abstract
This study evaluated the efficacy of a commercial volatile corrosion inhibitor (VCI) in mitigating the corrosion of carbon steel insulated with mineral wool insulation, especially as a retrofitted solution to corrosion under insulation (CUI) management. When VCI was added in dry insulation before the test solution was introduced, the severity of CUI was reduced after 14 d of exposure. However, when the exposure time was extended to 90 d, no significant mitigation effect was observed. Furthermore, VCI was ineffective when added to precorroded insulated systems, indicating that it could not be used as a retrofitted solution to alleviate CUI problems. A separate set of tests with bare steel samples exposed to 10 mL VCI in closed jars showed that VCI was adsorbed on the corrosion products but could not effectively impede the propagation of localized corrosion. The possible influences of insulation jacketing, insulation properties, VCI dosages, and dosing methods were also discussed, suggesting the need for further investigations.
Publisher
Association for Materials Protection and Performance (AMPP)
Subject
General Materials Science,General Chemical Engineering,General Chemistry