Temperature Effects on Two-Cell Field Impedance Testing of Epoxy and Polysulfide-Modified Epoxy Coatings

Author:

Cleveland Mack1ORCID,Merten Bobbi Jo2ORCID

Affiliation:

1. *Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843.

2. **Bureau of Reclamation, 6th Ave. & Kipling St. Denver, Colorado 80225.

Abstract

Two-cell field impedance spectroscopy provides coating condition assessment in situ, i.e., on coated structures. This study evaluated the dependence of impedance data on environmental conditions encountered during testing, especially temperature. Field impedance spectroscopy measurements were applied to two coated steel substrates over the course of a diurnal heating-cooling cycle. One coated substrate provided a high-barrier epoxy and the second a low-barrier polysulfide-modified epoxy (polysulfide). The temperature range examined was approximately 80 degrees Fahrenheit (ºF) to 110ºF for air, surface, and solution temperature, with baseline measurements made at 70ºF. The results showed coating impedance decreases as the coating surface temperature increases. The coatings showed time-dependent recovery of their initial properties during the cooling cycle, with the greater hysteresis observed by the high-barrier epoxy. Linear regression of temperature and impedance provided a strong correlation, with R2 exceeding 0.80. Therefore, field impedance data with varied temperatures can be corrected via a linear regression formula derived by measuring one sample at two or more temperatures within the encountered range. Coating surface temperature is preferred based on a stronger correlation with impedance than atmospheric or test cell solution temperatures. An Arrhenius relationship is also acceptable for temperature correction and may be preferred where the highest accuracy is needed. This correlation had an R2 of 0.96 or higher, demonstrating a logarithmic dependence of impedance on the inverse of the absolute temperature, i.e., the temperature in Kelvin. The effect of humidity on the impedance was low and could not be resolved from the strongly correlated effect of temperature. The repeated impedance testing, about 40 repetitions at a single location, applied in this experiment showed no discernable effect on the coating impedance, suggesting the voltage amplitudes utilized of 100 mV for low-barrier polysulfide and 500 mV for high-barrier epoxy were nondestructive.

Publisher

Association for Materials Protection and Performance (AMPP)

Subject

General Materials Science,General Chemical Engineering,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3