Liquid Chromatographic-Electrospray Ionization-Mass Spectrometry Method for the Simultaneous Determination of Gramicidin, Neomycin & Triamcinolone Acetonide and Characterization of Novel Forced Degradation Products

Author:

Gaddey Pridhvi Krishna1ORCID,Sundararajan Raja1ORCID

Affiliation:

1. Department of Pharmaceutical Analysis, GITAM Institute of Pharmacy, GITAM (Deemed to be University), Visakhapatnam-530045, India

Abstract

The dosage form iotrim (gramicidin, neomycin and triamcinolone) is a combination of two antibiotics (gramicidin and neomycin) and a steroid (triamcinolone). The antibiotics work by killing the bacteria that cause infections. The steroid blocks the action of chemical messengers (prostaglandins) that make the affected area red, swollen and itchy. Consequently, there was still a need to develop a simple, less time consuming and economical method for the simultaneous determination of gramicidin, neomycin and triamcinolone acetonide. The current work is an effort to develop a fast and reproducible LC-MS technique for the simultaneous estimation of gramicidin, neomycin and triamcinolone acetonide. The objective of the present procedure was to validate and develop a precise and accurate liquid chromatography-mass spectrometry (LC-MS) technique for the simultaneous quantification of gramicidin, neomycin and triamcinolone acetonide. Gramicidin, neomycin and triamcinolone acetonide were monitored on Shimadzu-8045 mass spectrometer equipped with electro spray ionization interface. The retention times of gramicidin, neomycin and triamcinolone acetonide were found at 9.145 min, 7.273 min and 2.435 min, respectively. The limit of detection (LOD) results for gramicidin, neomycin and triamcinolone acetonide were observed to be 0.15, 1.5 and 0.6 μg/mL, respectively while the limit of quantification (LOQ) results were observed to be 0.5, 5, 2 μg/mL concentration, respectively. The linear range for gramicidin, neomycin and triamcinolone acetonide were found in the concentration ranges from 1.25-7.5 μg/mL, 12.5-75 μg/mL and 5-30 μg/mL with regression coefficient of 0.9991, 0.9996, 0.9999, respectively. Accuracy values for gramicidin, neomycin and triamcinolone acetonide were found to be in the range of 98.64%, 99.4%, 99.5% respectively. The % RSD for six replicates in precision was less than 2%. According to ICH Q2(R1) recommendations, this method was successfully tested with LC-MS to confirm the chemical structures of newly produced degradation products of triamcinolone acetonide and neomycin. The developed process was validated efficaciously as per ICH guidelines.

Publisher

Asian Journal of Chemistry

Subject

General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3