Validation of a commercially available mobile application for velocity-based resistance training

Author:

Trowell Danielle Anne1,Carruthers Collins Angus G.1,Hendy Ashlee M.2,Drinkwater Eric James1,Kenneally-Dabrowski Claire1

Affiliation:

1. Centre for Sport Research, Institute for Physical Activity and Nutrition, Deakin University, Burwood, Victoria, Australia

2. Institute for Physical Activity and Nutrition, Deakin University, Waurn Ponds, Victoria, Australia

Abstract

Background Velocity-based training (VBT) is commonly used for programming and autoregulation of resistance training. Velocity may also be measured during resistance training to estimate one repetition maximum and monitor fatigue. This study quantifies the validity of Metric VBT, a mobile application that uses camera-vision for measuring barbell range of motion (RoM) and mean velocity during resistance exercises. Methods Twenty-four participants completed back squat and bench press repetitions across various loads. Five mobile devices were placed at varying angles (0, ±10, and ±20°) perpendicular to the participant. The validity of Metric VBT was assessed in comparison to Vicon motion analysis using precision and recall, Lin’s concordance correlation coefficient, and Bland-Altman plots. Proportional bias was assessed using linear regression. Results Metric VBT accurately detected over 95% of repetitions. It showed moderate to substantial agreement with the Vicon system for measuring RoM in both exercises. The average Limits of Agreement (LoA) for RoM across all camera positions were −5.45 to 4.94 cm for squats and −5.80 to 3.55 cm for bench presses. Metric VBT exhibited poor to moderate agreement with the Vicon system for measuring mean velocity. The average LoA for mean velocity were 0.03 to 0.25 m/s for squats and −5.80 to 3.55 m/s for bench presses. A proportional bias was observed, with bias increasing as repetition velocity increased. Conclusions Metric VBT’s wide LoA for measuring RoM and mean velocity highlights significant accuracy concerns, exceeding acceptable levels for practical use. However, for users prioritizing repetition counts over precise RoM or mean velocity data, the application can still provide useful information for monitoring workout volume.

Publisher

PeerJ

Reference32 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3