Investigation, biokinetic calculation, and modelling of a real combined industrial wastewater biological treatment process by activated sludge models

Author:

Bina Bijan12,Nikzad Nasim1,Ghodsi Soudabeh1,Momeni Seyed Alireza3,Movahedian Attar Hossein12,Janati Mahsa4,Mohammadi Farzaneh12

Affiliation:

1. Department of Environmental Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran

2. Environment Research Center, Research Institute for Primordial Prevention of Non-Communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran

3. Small Industries and Industrial Parks Organization, Isfahan, Iran

4. Department of Civil Engineering, Lakehead University, Thunder Bay, Canada

Abstract

Background: Treatment of combined industrial wastewater from industrial parks is one of the most complex and difficult wastewater treatment processes. Also, the accuracy of biological models for the prediction of the performance of these processes has not been sufficiently evaluated. Therefore, in this study, the International Association on Water Quality (IAWQ(-Activated Sludge Model No. 1 (ASM1) was implemented for the Jey industrial park in Isfahan province, Iran. Methods: The Jey IPWWTP process is a combination of anaerobic and aerobic biological processes. To evaluate the overall performance of IPWWTP, organic compounds, suspended solids, nutrients, attached biomass, and some operating parameters were measured during 6 months. Then, the biokinetic coefficients of aerobic processes were determined using Monod equations. Finally, the aerobic processes were modeled using ASM1 implemented in STOAT software. Results: The values of the biokinetic coefficients K, Y, Ks, Kd, and µmax were calculated as 2.7d- , 0.34 mg VSS/mg COD, 133.36 mg/L COD, 0.03d- , and 0.93d- , respectively. Based on the default coefficients and conditions of the ASM model, the difference between the experiments and model prediction was about 2 to 98%. After calibrating the ASM model, the difference between the experiments and prediction in all parameters was reduced to less than 10%. Conclusion: Investigations showed that the default coefficients and operation conditions of the ASM1 model do not have good predictability for complex industrial wastewaters and the outputs show a low accuracy compared to the experiments. After calibrating the kinetic coefficients and operating conditions, the model performance is acceptable and the predictions show a good agreement with the experiments.

Publisher

Maad Rayan Publishing Company

Subject

Chemical Health and Safety,Public Health, Environmental and Occupational Health,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3