The positive association between various demographic characteristics and peak expiratory flow in employees of Zanjan university of medical sciences

Author:

Ghodrati Samad1ORCID,Kiasatfar Jafar2,Parsamanesh Negin3ORCID,Alian Samakkhah Shohreh4,Asadi-Khiavi Masoud56ORCID,Pezeshgi Aiyoub13ORCID

Affiliation:

1. Department of Internal Medicine, School of Medicine, Zanjan University of Medical Sciences, Zanjan, Iran

2. Department of Internal Medicine, School of Medicine, West Azarbaijan University of Medical Sciences, Urmia, Iran

3. Zanjan Metabolic Diseases Research Center, Zanjan University of Medical Sciences, Zanjan, Iran

4. Department of Food Hygiene, Faculty of Veterinary Medicine, Amol University of Special Modern Technologies (AUSMT), Amol, Iran

5. Zanjan Applied Pharmacology Research Center, Zanjan University of Medical Sciences, Zanjan, Iran

6. Department of Pharmacotherapy, School of Pharmacy, Zanjan University of Medical Sciences, Zanjan, Iran

Abstract

Introduction: Peak expiratory flow (PEF) is a reliable criterion for assessing respiratory capacity, and has a wide range of clinical application as a marker of asthma control. However, its wide variability undermines its efficacy. Objectives: This study was designed to evaluate PEF changes in staff of Zanjan University of Medical Sciences. Patients and Methods: Four hundred employees of this university participated in this cross-sectional study. Their PEF values were measured using peak flow meter in the morning at 8 AM and in the afternoon at 2 PM by three times for each individual, and then the highest amount of PEF was recorded about for measurement. Results: Obviously, PEF values were higher in the afternoon (43865 L/min) in comparison to the morning measurements (404.60 L/min) by paired t test (P<0.001). In addition, mean of PEF in the males was higher than the females in the morning (469.77 L/min, versus 355.94 L/min; independent t test, P<0.001), and also PEF mean of the morning and afternoon was higher in the males than females (404.6 L/min, versus 338.65 L/min, independent t test, P<0.001). Additionally, the variability level in the males and females was 8.39±6 and 8.47±4 L/min, respectively. There was a high correlation between the level of PEF variability and height (5.1). Meanwhile, a moderate correlation between PEF level and body mass index (BMI) was detected (1.47). There was not any correlation between the level of PEF and age. Conclusion: Based on our findings, PEF inter-individual variability depends on age, gender height, and BMI however, it is worthwhile that this PEF inter-individual variability to be measured just until 4 PM. All these variables were obtained under the range of 20%; however, relying on references, the variability of 20% is considered as normal.

Publisher

Maad Rayan Publishing Company

Subject

Immunology and Microbiology (miscellaneous),Hematology,Immunology,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3