Negative fluid displacement: an alternative method to assess patency of arterial line cannulation

Author:

DeBois William J1,Girardi Leonard N2,Lee Leonard Y2,Mack Charles2,Elmer Barbara2,McCusker Kevin2,McVey James2,Krieger Karl H2,Isom O Wayne2

Affiliation:

1. New York-Presbyterian Hospital, New York Weill Cornell Center, New York, USA,

2. New York-Presbyterian Hospital, New York Weill Cornell Center, New York, USA

Abstract

Optimal flow rate with minimal pressure gradient is the goal of arterial cannulation for cardiopulmonary bypass (CPB). Misplacement of the arterial cannula or vascular pathology can lead to hemolysis or intimal damage with subsequent aortic dissection. The risk of dissection with aortic cannulation is low, 0.04-0.2% for ascending aortic cannulation and 0.2-3% for femoral cannulation. However, dissection-related mortality is significant. Common methods for assessing adequacy of arterial cannulation include minimal pressure when injecting 100-mL boluses and the presence of pulsation in the cannula. Using these techniques, misplacement of the cannula can be masked due to the small amount of volume that is transfused during the assessment. Displacement of fluid into a cannula that is in a false lumen or close to the intimal surface may not indicate a misplaced arterial cannula. Negative fluid displacement is an alternative method of evaluating the integrity of arterial cannulation. During retrograde arterial priming (RAP), fluid is drained from the arterial cannula into a collection bag. Absence of fluid return or a flow B /500 mL/minute is indicative of either arterial line occlusion or cannula misplacement. At this point, the arterial cannula can be repositioned prior to instituting CPB. Since using this technique in over 13 000 bypass procedures, we have had only one dissection. This one event occurred during partial occlusion clamping of the ascending aorta. With increased use of femoral cannulation for minimally invasive cardiac surgical procedures, this RAP technique can enhance the perfusionist’s and the surgeon’s ability to safely perform bypass in the presence of higher dissection risk.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Iatrogenic Aortic Dissection Associated With Cardiac Surgery: A Narrative Review;Journal of Cardiothoracic and Vascular Anesthesia;2021-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3