The Importance of Glycerin-Containing Negative Control Tests in Allergy Research Studies that Use Intradermal Skin Tests

Author:

Hurst David S.12,Gordon Bruce R.12,Krouse John H.12

Affiliation:

1. Boston, Cambridge, and Hyannis, Massachusetts, and Detroit, Michigan

2. From Tufts University (Dr Hurst), Department of Otolaryngology and Laryngology, Harvard University (Dr Gordon), Massachusetts Eye and Ear Infirmary (Dr Gordon), Cape Cod Hospital (Dr Gordon), and Wayne State University (Dr Krouse).

Abstract

OBJECTIVE: We sought to assess skin whealing with glycerin-containing control injections for intradermal skin tests. DESIGN: Observational. METHODS: Wheal sizes were measured at 0, 10, and 15 minutes after intradermal injection of 0.01 and 0.02 mL of phenolated normal saline and 0.5% and 5% concentrations of glycerin in the same quantity of phenolated saline. RESULTS: Intradermal injection of 0.01 mL of phenolated saline produced an average 4.9-mm wheal, which expanded to 5.2 mm at 10 minutes and to 6.0 mm at 15 minutes. Intradermal injection of 0.02 mL of phenolated saline produced a 6.4-mm wheal, which expanded to 7.0 mm at 10 minutes and 8.0 mm at 15 minutes. The addition of glycerin produced proportionally larger wheals. CONCLUSIONS: Because glycerin increases whealing beyond that with phenolated saline, skin tests containing glycerin must be compared with glycerin-containing negative controls. Intradermal skin tests that fail to compare findings in this manner contain an inherent methodologic flaw and are uninterpretable. A major issue in allergy testing is deciding whether the observed skin response is truly indicative of the patient having a clinically relevant, IgE-mediated reaction. 1 Skin test results are influenced by many variables, including patient skin response, specific technique, and tester consistency. Wheal measurement, comparisons with positive and negative control solutions, and interpretation are of equal importance. The development of in vitro methods for allergy diagnosis has helped to independently verify the accuracy of skin tests. In some cases, poor standardization of antigen sources and testing techniques has been shown to lead to discrepancies between skin tests and in vitro IgE antibody results of more than 100-fold. 2 It is also possible for skin tests to be falsely negative, as has been shown by comparing IgE blood tests with both skin tests and challenge tests. 3 Conversely, skin tests may be falsely positive because of nonspecific irritants, such as glycerin, present in allergen solutions. 4,5 Recommendations for immunotherapy must be based on clinical appropriateness as related to valid testing of proposed therapeutic agents. Recent reports by Nelson et al 6 and Wood et al 7 have suggested that skin prick tests (SPTs), even when negative, are sufficiently sensitive to diagnose clinical atopy without the need for further intradermal skin tests (IDTs). Both authors describe performance of a single IDT with injection of 0.02 mL of antigen solution. The basic tenant of their methodology is that all wheals resulting from an IDT measuring 6 mm or greater, accompanied by erythema, are to be recorded as positive. Nelson et al took measurements at 15 minutes, and Wood et al took measurements at an unspecified time. We were concerned that their methodology for IDTs created many false-positive results. This led to the condemnation of IDTs by these authors, stating that “a positive intradermal skin test response to Timothy grass in the presence of a negative skin prick test response to Timothy grass did not indicate the presence of clinically significant sensitivity to Timothy grass.” 6 We found the conclusion based on their particular IDT method to be suspect for 2 reasons: (1) it categorically assumes that an injection of 0.02 would produce a wheal of less than 6 mm and (2) it ignores the effects of small concentrations of the preservative glycerin, used in most all allergy test solutions, on whealing. Either assumption would lead to frequent false-positive skin test interpretations and discredit 60 years of intradermal testing. We therefore sought to evaluate control tests appropriate for use with the methodologies published in the general allergy literature to determine whether a 6-mm wheal with erythema should appropriately be interpreted as a positive or as a negative test.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3