SMART Trigger versus Flow and Pressure trigger performance during auto-PEEP

Author:

Fujiuchi Bradley,daoud ehabORCID

Abstract

Background Intrinsic positive end-expiratory pressure (auto-PEEP) is a common problem in mechanically ventilated patients, which can lead to adverse effects on patients comfort, hemodynamics, lung mechanics and gas exchange. Triggering systems play a crucial role in the delivery of mechanical ventilation, and advancements in smart triggering technology aim to optimize patient-ventilator synchrony. This bench study aims to compare the performance of the novel SMART Trigger to traditional pressure and flow triggers in the context of auto-PEEP. Methods A lung model simulating severe obstructive pattern with high compliance (80 ml/cmH2O) and high resistance 30 cmH2O/L/s was connected to the Panther 5 ventilator (Origin Medical, California, USA). The mode was set at Volume Controlled with a tidal volume of 700 ml and mandatory breath per min (BPM) of 10/min and Inspiratory time of 2 seconds to intentionally create auto-PEEP. Simulated spontaneous breaths set at 20 BPM with increasing muscle pressure (Pmus) from -1 to maximum of -25 or till full trigger of all breaths. Three different triggering systems were evaluated: SMART Trigger (ST sensitivity 1 to 7), pressure trigger (-1 cmH2O), and flow trigger (1 l/min). The range of auto-PEEP levels induced increased incrementally with the increase in the respiratory rate ranging from 3 cmH2O for 10 BPM, 8 for 15 BPM, to 13 for 20 BPM. The following parameters were assessed for each triggering system: trigger sensitivity (defined as the number of breaths triggered above the mandatory breaths), and the trigger response time (time it takes from the beginning of muscle effort to the initiation of the breath. Results 100% of the breaths were triggered at Pmus (cmH2O) of -15 in the pressure trigger, -25 in flow trigger, -3 for ST1, -9 for ST2, -10 for ST3, -10 for ST4, -12 for ST5, -18 for ST 6, and -22 for ST 7. Trigger time (msec) for flow was 0.135 ± 0.02, for pressure 0.141 ± 0.04, for ST 1-4: 0.076 ± 0.03, for ST 5-7: 0.104 ± 0.04. Multivariate analysis of variance test showed significant difference between the time to trigger P <0.001. Conclusion This bench study highlights the potential advantages of SMART Trigger technology over conventional pressure and flow triggers during auto-PEEP. The SMART Trigger enhanced sensitivity and rapid response might contribute to improved patient-ventilator synchrony. Further research and clinical studies are warranted to validate these findings and explore the impact of smart trigger technology on patient outcomes in real-world scenarios. Keywords: SMART Trigger, Auto-PEEP, Trigger time

Publisher

Journal of Mechanical Ventilation

Subject

General Engineering

Reference18 articles.

1. 1. Navalesi P, Maggiore S. Chapter 10. Positive end-expiratory pressure. Tobin M.J.(Ed.), Principles and Practice of Mechanical Ventilation, 3e. McGraw Hill; 2013.

2. Effects of intrinsic PEEP on pulmonary gas exchange in mechanically ventilated patients;Brandolese;Eur Respir J,1993

3. Go with the flow-clinical importance of flow curves during mechanical ventilation: A narrative review;Hamahata;Can J Respir Ther,2020

4. 4. Chatburn RL, Mireles-Cabodevila E. Chapter 3. Basic Principles of Ventilator Design. In: Tobin MJ. eds. Principles and Practice of Mechanical Ventilation, 3e. McGraw Hill; 2013.

5. Flow versus pressure triggering in mechanically ventilated acute respiratory failure patients;Khalil;Egypt J Bronchol,2015