Affiliation:
1. Southwest State University
Abstract
THE PURPOSE. To consider issues related to the study of methods for determining the sources of violations of the quality of electrical energy in power supply systems, in particular consumers which create rapid voltage changes or voltage fluctuations that create rapid changes in the luminous flux in electric lighting installations. Show that electrical receivers with a sharply variable operating mode are sources of fluctuations in the consumed current and voltage in the electrical network of power supply systems, which in turn manifests itself in the form of unacceptable values of one of the indicators of the quality of electricity - flicker, defined as the subjective perception of fluctuations in the luminous flux of lighting devices. To study the possibilities of determining the places of occurrence of significant voltage fluctuations without the use of expensive and complex instruments for measuring flicker values in the electrical network. To develop a simplified method for determining the locations of electricity consumers that negatively affect the operation of electric lighting systems and, ultimately, the vision of personnel. Conduct a check on a computer model of a simplified method for determining the places of occurrence of voltage fluctuations that are inadmissible in their magnitude, which are expressed in the appearance of significant doses of flicker that exceed the standard values.METHODS. Solving the problem, a computer model was used, created in the Simulink extension package of the Matlab scientific and technical calculation system.RESULTS. The article describes the relevance of the problem, discusses the quality of electricity in power supply systems. It has been shown using experimental data that in electrical networks there is an excess of the standard values of flicker doses. The possibility of using interharmonic components of the mains voltage to determine the sources of unacceptable doses of flicker is considered. A simplified method for finding flicker sources based on obtaining the values of the derivatives of currents at various points of the electrical network is presented. Computer simulation of an electrical network diagram with electrical receivers, which have both calm and sharply variable nature of work, has been performed. It is shown that the use of the values of the derivatives of the current at various points of the electrical network makes it possible to identify the sources of the occurrence of unacceptable doses of flicker.CONCLUSION. The occurrence of significant rapid voltage changes in the electrical network negatively affects vision, which is inevitably accompanied by increased personnel fatigue and can lead to industrial injuries. The results obtained by the authors of the article show that it is possible to use it to determine the places of occurrence of large voltage fluctuations, which are manifested in unacceptable doses of flicker of the derivatives of currents. It should be taken into account when conducting surveys of power supply systems in order to use fairly simple hardware to identify sources of disturbance in the quality of electrical energy.
Publisher
Kazan State Power Engineering University
Subject
Pharmacology (medical),Complementary and alternative medicine,Pharmaceutical Science
Reference18 articles.
1. Kovernikova LI, Sudnova VV, Shamonov RG. Kachestvo elektricheskoj energii: sovremennoe sostoyanie, problemy i predlozheniya po ih resheniyu. Novosibirsk. Nauka; 2017.
2. Kovernikova LI, Tulsky VN, Shamonov RN. Electricity quality in the UES of Russia: Current problems and necessary solutions. Electricity: Transmission and distribution. 2016; 2 (35):28–38.
3. Dedov AV, Sikorskiy SP, Smirnov PS. Results of measurements of power quality indicators in power supply systems of enterprises and organizations. Omsk Scientific Bulletin. 2018; 2 (158):60–64. doi: 10.25206/1813-8225-2018-158-60-64.
4. Cherepanov VV, Kalinina EA. Calculation of the short-term dose of flicker arising from the stochastic nature of the change in electrical loads. Fundamental research. 2016; 5(11): 960-967.
5. Kornilov GP, Barankova II, Lukyanov GI, Karyakin AL Calculation of the short-term dose of flicker in the electrical networks of enterprises. Electrotechnical systems and complexes. 2019; 3:10-15. doi: 10.18503/2311-8318-2019-3(44)-10-15.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献