Influence of the type of load graphs on the service life transformers 33/11 Kv at substation "Kabun-1" (Syrian Arab Republic)

Author:

Abdullazyanov E. Yu.1,Gracheva E. I.1ORCID,Alzakkar A.1,Valtchev S.2,Mestnikov N.3

Affiliation:

1. Kazan State Power Engineering University

2. University NOVA of Lisbon

3. North-Eastern Federal University named M.K. Ammosov

Abstract

Power transformers are one of the main components of power supply systems needed to reliably supply electricity to consumers. As we know, the value of the allowable load of transformers is determined by the value of the allowable heating of structural elements, on which the service life of transformer period depends. Reliable data on the technical condition of the structural elements of transformers is the decisive information for making decisions on the replacement and maintenance of transformers. METHODS. To assess the service life of transformers, methods were used to evaluate the statistical parameters of consumer load graphs, load factors and the heating temperature of the windings of transformers with a capacity of Sn.T = 20 MVA, a voltage of 33/11 kV at substation Kabun-1. THE AIM. The aim of the work is to evaluate the service life of the transformers at substation Kabun-1 (Syrian Arab Republic) with various options for the type of load power consumption graph (first; second; third). THE RESULTS. The main statistical parameters of the characteristics of the original and proposed options of load power graphs (active, reactive and apparent) per day of transformers, the main electrical consumer of which is the spinning and weaving factory, are determined. Approximating functions of daily graphs of power loads of transformers, from which the spinning and weaving factory receives power (first and second approximations), have been developed. It is proved that with the considered options for shifting the time of the start of work of electrical consumers - with the third option -the maximum load power is reduced by 12.8%, load variation is reduced from 0.33 to 0.17 in relation to the second option for the subdivisions of the spinning and weaving factory. It has been established that for all the considered options, the average value of the load power of the transformers at substation Kabun-1 is constant. The laws of change in the relative value of the service life of transformers during the implementation of various technical measures are determined.

Publisher

Kazan State Power Engineering University

Subject

Pharmacology (medical),Complementary and alternative medicine,Pharmaceutical Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3