Dimensional Change of Elastomeric Materials after Immersion in Disinfectant Solutions for Different Times

Author:

Carvalhal Cintia Iara Oda,de Mello José Antônio Nunes,Sobrinho Lourenço Correr,Correr Américo Bertolazzo,Sinhoreti Mário Alexandre Coelho

Abstract

ABSTRACT Aim The aim of this study was to evaluate the influence of immersion period in two disinfectant solutions on dimensional change of four elastomeric impression materials. Materials and methods Four representative materials of each class of elastomers: Xantopren (polydimethylsiloxane—PDS), Express (polyvinyl siloxane—PVS); Permlastic (polysulfide— PS) and Soft Impregum (polyether—EP) were mixed according to manufacturers’ instructions and then inserted into a metal matrix prepared according to the specification of ISO 4823. The molds were removed from the matrix after 7 minutes and immersed in disinfectant solutions (sodium hypochlorite 0.5 and 2% glutaraldehyde) for 5, 10, 20, 30 and 60 minutes (n = 7), except the control group, which was not immersed. Once removed from solutions, the test samples were washed in water for 15 seconds, dried and measured three times, using a comparative optical microscope, with accuracy of 0.0005 mm. The analysis of variance with three criteria and Tukey's test with significance level of 5% showed that differences in linear dimensions of the materials analyzed were not statistically significant (p > 0.05) after soaking in sodium hypochlorite 0.5 and 2% glutaraldehyde, for the tested periods of time. Clinical significance Combinations of molding material and disinfecting solution can be used in the dental clinic for infection control, without changing the dimensional molds, for immersion periods not longer than 20 minutes. How to cite this article Carvalhal CIO, de Mello JAN, Sobrinho LC, Correr AB, Sinhoreti MAC. Dimensional Change of Elastomeric Materials after Immersion in Disinfectant Solutions for Different Times. J Contemp Dent Pract 2011;12(4): 252-258.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Reference60 articles.

1. Guandallini SL. Bio Segurança. J Bras Orto Ortop Facial 1996;1:5-8.

2. Kimondollo PM. Guidelines for developing a dental laboratory infection-control protocol. Int J Prosthodont 1992;5:452-56.

3. Effect of disinfectant agents on dimensional stability of elastomeric impression materials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3