A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study

Author:

Shankar T,Rao N Venugopal,Gowd Snigdha,Ahmed Syed Tauqheer,Vinod V,Goud M Vikas

Abstract

ABSTRACT Aim The aim of this study is to evaluate the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle. Materials and methods In this study, a total of 60 standardized maxillary record bases were fabricated with seven reference points as follows: • Point A Incisive papilla, • Point B and C Canine region on either side • Point E and G Midpoint of tuberosities on either side • Point F Midpoint of the line joining the two tuberosities • Point D Midpoint between the line joining A and F Group A Ten maxillary record bases were fabricated by conventional clamping method and cured by long curing cycle. Group A’ Ten maxillary record bases were fabricated by New Press or RS tension clamping method and cured by long curing cycle. The distances between the reference points, i.e. A-B, A-C, A-D, D-F, B-E, C-G, E-F, F-G, B-D, D-G, C-D, D-E of all three thermoplastic denture base plates were measured and recorded with the help of travelling microscope and were used for comparison with the measured and recorded readings of processed acrylic denture bases. The data obtained was analyzed by using the one-way analysis of variance and HSD Multiple Comparison Test. Results The overall results of the study indicate that among all the denture bases cured by the two clamping systems and the long curing cycle, group A‘ were the most dimensionally stable, followed by control group A. Conclusion The study concluded that the denture bases fabricated by the New Press method using the long curing cycle would produce the most dimensionally stable denture bases. How to cite this article Shankar T, Gowd S, Ahmed ST, Vinod V, Goud MV, Rao NV. A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study. J Contemp Dent Pract 2012;13(6):842-849.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3