A Comparative Study of Impression Procedures for Distal Extension Removable Partial Dentures

Author:

Tavane Pradeep N,Abraham Sathish,Madihalli Anand U,Yadav Naveen S,Reddy P Manoranjan,Baiju G

Abstract

ABSTRACT Aim This study was carried out with the purpose of comparing three impression methods as to which of them placed tissues most favorably. Methods The methods used were Hindels method, selective tissue placement method and functional reline method. The measurements obtained were analyzed to determine which of the three impression methods placed the mucosal tissues maximally. To compare and measure tissue placements, autopolymerizing acrylic resin platforms were constructed to the height of the occlusal surfaces of the remaining teeth. 15 orthodontic buccal tubes were placed on each side of the platform. They were arranged in three sets of five and attached to the platform over selected reference regions by means of autopolymerizing resin. The selected reference areas were in anterior, middle and posterior areas of the ridge on either side. Results No significant difference was seen in tissue placement in the anterior middle and posterior regions in each of the three methods when each method was assessed separately. Selective tissue placement method placed the tissues maximally (7.547 mm) followed by Hindels method (7.2110 mm) and the least placement was by functional reline method (5.856 mm). Tissue placement was significantly higher in Hindels method as compared to functional reline method (p < 0.001). Conclusion Tissue placement was maximum in the posterior region, followed by the middle region and least in the anterior region of the mandibular ridge for all three methods. Selective tissue placement method showed the maximum overall tissue placement followed by the Hindels method and minimum placement was by functional reline method. Clinical significance Selective tissue placement method provided maximum overall tissue placement and can be a preferred technique for impression making for bilateral distal extension removable partial denture fabrication. How to cite this article Madihalli AU, Tavane PN, Yadav NS, Abraham S, Reddy PM, Baiju G. A Comparative Study of Impression Procedures for Distal Extension Removable Partial Dentures. J Contemp Dent Pract 2011;12(5):333-338.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3