Reliability of Orthopantomography and Cone-beam Computed Tomography in Presurgical Implant Planning: A Clinical Study

Author:

Gupta Megha,Sahota Jasjit,Bhatia Aditya,Singh Vishal,Soni Juhi,Soni Richa

Abstract

ABSTRACT Background Preoperative diagnosis and treatment planning are fundamental requirements to ensure success rate of implant. Cone-beam computed tomography (CBCT) provides all three dimensions and has been proved as a tool for radiology, especially in the success of implant. This study was conducted to evaluate the reliability of orthopantomography (OPG) and CBCT in presurgical implant planning. Materials and methods The study was conducted on 110 partially or completely edentulous adult patients (male 50 and female 60). Patient information regarding name, age, gender, and so forth was recorded. Thorough clinical examination was done to locate the edentulous site for the placement of implant. All patients were subjected to OPG and CBCT. The OPG was taken with digital panoramic unit (Planmeca) operating at 120 kVp, 2 mA, and exposure time of 17 seconds. The CBCT was taken using NewTom machine with field of view 11 × 8 cm and resolution of 0.3 × 0.3 × 0.3 mm operating at 120 kVp at 5 mA. NNT software with slice thickness of 0.1 mm was used in this study. Measurement of bone height and distance from anatomical structures was done on OPG, whereas bone height and bone width were measured on CBCT scan in all three planes, such as coronal plane, sagittal plane, and axial plane. The measurement was done by two experienced observers. Results The present study comprised 110 patients (male 50 and female 60). About 102 (16.7%) implants were placed in anterior region, and 508 (83.3%) implants were placed in posterior region. Implant site was incisor region (55), canine (30), premolar (250), and molar (275). The difference was significant (p < 0.01). Variations are usually observed in presurgical planning with CBCT and OPG. The length and width of implant remained unchanged in 90 and 85% of the cases respectively. In 8% of cases, OPG revealed more length of implant than CBCT, whereas only in 2% cases CBCT revealed more length of implant than OPG. The difference was significant (p < 0.05). When we compared the diameter, OPG revealed more diameter in 10% of cases, whereas CBCT only revealed 5% of cases. The difference was significant (p < 0.05). Observer found CBCT as effective in 95% of cases and ineffective in only 5% of cases, whereas OPG was effective in 78% of cases and ineffective in 22% of cases. The different was significant (p < 0.05). Conclusion The CBCT being three-dimensional provides detailed information that two-dimensional radiographs cannot offer, which aids in precision to further improve the entire implant process. Clinical significance In recent times, implant has become the treatment of choice for edentulous patients. The CBCT has increased the success rate of implant due to its high resolution, ability to demonstrate anatomical structures more effectively than other radiographic diagnostic tools. How to cite this article Sahota J, Bhatia A, Gupta M, Singh V, Soni J, Soni R. Reliability of Orthopantomography and Conebeam Computed Tomography in Presurgical Implant Planning: A Clinical Study. J Contemp Dent Pract 2017;18(8):665-669.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3