The Accuracy of Hemoglobin A1c and Fructosamine Evaluated by Long-Term Continuous Glucose Monitoring in Patients with Type 2 Diabetes Undergoing Hemodialysis

Author:

Bomholt Tobias,Rix Marianne,Almdal Thomas,Knop Filip K.ORCID,Rosthøj SusanneORCID,Heinrich Niels SøndergaardORCID,Jørgensen Morten B.,Larsson AndersORCID,Hilsted Linda,Feldt-Rasmussen Bo,Hornum Mads

Abstract

<b><i>Introduction:</i></b> The accuracy of hemoglobin A1c (HbA1c) as a glycemic marker in patients with type 2 diabetes (T2D) receiving hemodialysis (HD) remains unknown. To assess accuracy, we compared HbA1c and fructosamine levels with interstitial glucose measured by continuous glucose monitoring (CGM) in patients with T2D receiving HD. <b><i>Methods:</i></b> Thirty patients in the HD group and 36 patients in the control group (T2D and an estimated glomerular filtration rate &#x3e;60 mL/min/1.73 m<sup>2</sup>) completed the study period of 17 weeks. CGM (Ipro2<sup>®</sup>, Medtronic) was performed 5 times for periods of up to 7 days (with 4-week intervals) during a 16-week period. HbA1c (mmol/mol), the estimated mean plasma glucose from HbA1c (eMPGA1c [mmol/L]) and fructosamine (μmol/L) was measured at week 17 and compared with mean sensor glucose levels from CGM. <b><i>Findings:</i></b> In the HD group, mean sensor glucose was 1.4 mmol/L (95% confidence interval [CI]: 1.0–1.8) higher than the eMPGA1c, whereas the difference for controls was 0.1 mmol/L (95% CI: −0.1–[0.4]; <i>p</i> &#x3c; 0.001). Adjusted for mean sensor glucose, HbA1c was lower in the HD group (−7.3 mmol/mol, 95% CI: −10.0–[−4.7]) than in the control group (<i>p</i> &#x3c; 0.001), with no difference detected for fructosamine (<i>p</i> = 0.64). <b><i>Discussion:</i></b> HbA1c evaluated by CGM underestimates plasma glucose levels in patients receiving HD. The underestimation represents a clinical challenge in optimizing glycemic control in the HD population. Fructosamine is unaffected by the factors affecting HbA1c and appears to be more accurate for glycemic monitoring. CGM or fructosamine could thus complement HbA1c in obtaining more accurate glycemic control in this patient group.

Publisher

S. Karger AG

Subject

Nephrology,Hematology,General Medicine

Reference20 articles.

1. Beck RW, Bergenstal RM, Cheng P, Kollman C, Carlson AL, Johnson ML, et al. The relationships between time in range, hyperglycemia metrics, and HbA1c. J Diabetes Sci Technol. 2019;13(4):614–26.

2. Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ. Translating the A1C assay into estimated average glucose values. Diabetes Care. 2008;31(8):1473–8.

3. Vos FE, Schollum JB, Coulter CV, Manning PJ, Duffull SB, Walker RJ. Assessment of markers of glycaemic control in diabetic patients with chronic kidney disease using continuous glucose monitoring. Nephrology. 2012 Feb;17(2):182–8.

4. Riveline JP, Teynie J, Belmouaz S, Franc S, Dardari D, Bauwens M, et al. Glycaemic control in type 2 diabetic patients on chronic haemodialysis: use of a continuous glucose monitoring system. Nephrol Dial Transpl. 2009;24:2866–71.

5. Hayashi A, Takano K, Masaki T, Yoshino S, Ogawa A, Shichiri M. Distinct biomarker roles for HbA1c and glycated albumin in patients with type 2 diabetes on hemodialysis. J Diabetes Complications. 2016;30(8):1494–9.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3