Mirioglu SafakORCID,Kazancioglu Rumeyza,Cebeci EgemenORCID,Eren NecmiORCID,Sakaci Tamer,Alagoz Selma,Tugcu Murat,Tuglular Serhan,Sumbul Bilge,Seyahi Nurhan,Ozturk Savas

Abstract

Introduction: Data regarding inactivated vaccines for SARS-CoV-2 in patients undergoing maintenance hemodialysis (MHD) are limited. We aimed to investigate humoral responses induced by CoronaVac compared to BNT162b2 in this population. Methods: In this multicenter prospective cohort study, adult patients undergoing MHD who lacked a history of COVID-19 and decided to get vaccinated with BNT162b2 or CoronaVac were enrolled. Participants provided serum samples before, 1 and 3 months after 2 doses. Anti-SARS-CoV-2 IgG antibodies against receptor-binding domain of the virus were measured, and levels ≥50 AU/mL were considered as positive. Breakthrough infections and adverse events were recorded. Results: Ninety-two patients were included, 68 (73.9%) of whom were seronegative at baseline. BNT162b2 and CoronaVac were administered in 38 (55.9%) and 30 (44.1%) patients. At 1 month, seropositivity was 93.1% in BNT162b2 and 88% in CoronaVac groups (p = 0.519). Quantitative antibody levels were significantly higher in BNT162b2 (p < 0.001). At 3 months, both seropositivity (96.4% and 78.3%, p = 0.045) and antibody levels (p = 0.001) remained higher in BNT162b2 compared to CoronaVac. Five patients (7.4%) experienced breakthrough COVID-19. Adverse events were more frequent with BNT162b2, although all of them were mild. Multiple linear regression model showed that only vaccine choice (BNT162b2) was related to the humoral response (β = 0.272, p = 0.038). Seropositive patients at baseline (n = 24) had higher antibody levels at any time point. Conclusions: BNT162b2 and CoronaVac induced humoral responses in naïve patients undergoing MHD, which were more robust and durable for 3 months after BNT162b2. Both vaccines created high antibody levels in patients who were seropositive at baseline.

Publisher

S. Karger AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3