Rapid and Effective Elimination of Myoglobin with CytoSorb<sup>®</sup> Hemoadsorber in Patients with Severe Rhabdomyolysis

Author:

Albrecht FredericORCID,Schunk Stefan,Fuchs Maren,Volk Thomas,Geisel Juergen,Fliser Danilo,Meiser Andreas

Abstract

<b><i>Introduction:</i></b> Rhabdomyolysis is characterized by destruction of muscle fibers by various causes and is diagnosed by increased creatine kinase concentrations in the blood. Myoglobin released into the blood may cause acute kidney injury. In this randomized controlled study, we hypothesized that myoglobin elimination would be faster when a hemoadsorber was added to a continuous veno-venous hemodialysis (CVVHD). <b><i>Methods:</i></b> Four patients in the control group received CVVHD with a high cut-off hemofilter using high blood and dialysate flows for 48 h. Four patients in the CytoSorb group received the same treatment, but in addition, the hemoadsorber CytoSorb<sup>®</sup> was inserted in front of the hemofilter and replaced once after 24 h. Blood samples were drawn simultaneously before (pre) and after (post) the hemofilter or else the hemoadsorber, after 5 and 30 min, as well as after 2, 4, 8, and 24 h. All measurements were repeated the next day after the hemoadsorber had been renewed in the CytoSorb group. Primary outcome was the area under the curve (AUC) of the relative myoglobin concentrations as percent of baseline. To evaluate the efficacy of myoglobin removal, relative reductions in myoglobin concentrations during one passage through each device at each time point were calculated. <b><i>Results:</i></b> Patients in the CytoSorb group had a significantly lower AUC during the first 24 h (42 ± 10% vs. 63 ± 6%, <i>p</i> = 0.029) as well as during the observation period of 48 h (26 ± 7% vs. 51 ± 12%, <i>p</i> = 0.029). The relative reductions for myoglobin were considerably higher in the CytoSorb group compared to the control group during the first 8 h. <b><i>Conclusion:</i></b> Myoglobin concentrations declined considerably faster when CytoSorb was added to a CVVHD. When compared to a high-cut-off hemofilter, efficacy of CytoSorb in myoglobin elimination was much better. Because of saturation after 8–12 h an exchange may be necessary.

Publisher

S. Karger AG

Subject

Nephrology,Hematology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3