Abstract
The goal of this study was to investigate contralateral hearing aid (HA) use after unilateral cochlear implantation and to identify factors of influence on the occurrence of a unilateral cochlear implant (CI) recipient becoming a bimodal user. A retrospective cross-sectional chart review was carried out among 77 adult unilateral CI recipients 1 year after implantation. A bimodal HA retention rate of 64% was observed. Associations with demographics, hearing history, residual hearing and speech recognition ability were investigated. Better pure-tone thresholds and unaided speech scores in the non-implanted ear, as well as a smaller difference in speech recognition scores between both ears, were significantly associated with HA retention. A combined model of HA retention was proposed, and cut-off points were determined to identify those CI recipients who were most likely to become bimodal users. These results can provide input to clinical guidelines concerning bimodal CI candidacy.
Subject
Speech and Hearing,Sensory Systems,Otorhinolaryngology,Physiology
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献