47 Consecutive Cases of Pipeline Flex Flow Diversion Utilizing a Novel Large-Bore Intracranial Intermediate Catheter: Nuances and Institutional Experience with the Syphontrak

Author:

Lin Li-Mei,Jiang Bowen,Bender Matthew T.,Westbroek Erick M.,Campos Jessica K.,Tamargo Rafael J.,Huang Judy,Coon Alexander L.,Colby Geoffrey P.

Abstract

Background: The increasing complexity of modern neurointerventions has necessitated a shift in intracranial access techniques towards more robust distal support platforms. Here we present our experience with the Syphontrak Support Catheter (Codman Neuro, Raynham, MA, USA) in the triaxial platform for the implantation of the second-generation Pipeline Flex embolization device (PED Flex; Medtronic Neurovascular, Irvine, CA, USA). Methods: We retrospectively identified patients who underwent PED Flex treatment utilizing the Syphontrak at a single institution. The procedural data collected included parent artery tortuosity, patient demographics, aneurysm characteristics, other equipment utilized, and catheter-related complications. Results: A total of 47 consecutive aneurysm flow diversions were successfully performed using the Syphontrak. The patients’ age ranged from 25 to 80 years (mean 57.3 ± 11.6) and 85% were women. The average aneurysm size was 4.8 ± 2.7 mm (range 2–14). All cases were in the anterior circulation, with 6 (12%) aneurysms located beyond the internal carotid artery termination. Significant cervical carotid tortuosity was present in 23% (11/47) of the cases and moderate-to-severe cavernous tortuosity (cavernous grade ≥2) in 51% (24/47) of the cases. The mean fluoroscopy time was 36.6 ± 14.8 min. In 12/47 cases (26%), vasospasm prophylaxis with intra-arterial verapamil infusion was performed. The Syphontrak was tracked to the intended distal position in all cases, with a 100% technical success of PED Flex implantation. Forty-six (98%) of the 47 patients were discharged home after an average length of stay of 1.38 days. No iatrogenic catheter-related vessel injury occurred. Transient, minor neurological morbidity occurred in 3 cases (6%) and 1 patient had a minor ischemic event (NIHSS score < 4) in the periprocedural period. Conclusion: The Syphontrak is a new large-bore, multi-durometer intermediate catheter (IC) designed for use in modern neurointerventional procedures. We have shown its utility in 47 successful cases of PED Flex flow diversion of a wide range of complexity. The IC provides robust and atraumatic distal intracranial access while also providing an enhanced image quality with its large 0.060″ inner diameter.

Publisher

S. Karger AG

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Surgery

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3