Prospective Analysis of Versatility and User Satisfaction with a Novel Single-Use Cystoscope with Working Channel

Author:

Lütfrenk ThomasORCID,Neisius Andreas,Rausch SteffenORCID,Salem Johannes,Kuru Timur H.

Abstract

Introduction: In the present study, a prospective systematic assessment of the clinical utility of the Ambu® aScopeTM 4 Cysto Reverse Deflection with regard to image quality, maneuverability, and navigation in an outpatient and inpatient setting was performed. Materials and Methods: A prospective multicenter study was performed for evaluation of the instrument during routine cystoscopy. We evaluated the clinical performance of the instruments using a standardized user questionnaire in different categories including image quality, treatment success, imaging of all areas of the urinary bladder, quality of navigation, flexibility of the endoscope, and satisfaction with the device. Statistical analyses were performed by SPSS using the Kruskal-Wallis and Wilcoxon-Mann-Whitney tests. A p value of p ≤ 0.05 was defined as statistically significant. Results: A total of 200 cystoscopies were performed, and the questionnaire response rate was 100%. The image quality was rated as very good in 65.5% (n = 131), good in 30.5% (n = 61), and neutral in 4% (n = 8) of cases. The criteria for poor or very poor were not mentioned. The characteristic “treatment success based on image quality” was also evaluated as very good in 49% (n = 98) and good in 50.5% (n = 101). The analysis revealed a very good or good overall impression of the examiners in all cases. Replacement of the cystoscope was not necessary during any of the examinations. However, in 3 cases, technical difficulties were documented. Further analysis of the data showed that physicians with less professional experience rated the visualization of the urinary bladder (p = 0.007) and the treatment success with regard to image quality significantly worse (p = 0.007). Conclusion: The Ambu® aScope™ 4 Cysto Reverse Deflection shows high satisfaction values among users in clinical routine. In analogy to other studies with flexible endoscopes, urologists with more professional experience show higher satisfaction values than examiners with less training in flexible endoscopy.

Publisher

S. Karger AG

Subject

Urology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Five historical innovations that have shaped modern urological surgery;Journal of Perioperative Practice;2023-12-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3