Comparison of Different Internal Limiting Membrane Peeling Sizes for Idiopathic Macular Holes: A Systematic Review and Meta-Analysis

Author:

Qi Biying,Zhang Ke,Yang Xiaohan,Wu Xijin,Wang Xinbo,Liu Wu

Abstract

Background: Although internal limiting membrane (ILM) peeling facilitates macular hole (MH) closure and reduces late hole reopening, it brings some detrimental consequences to the retinal microstructure and functional outcomes. So far, previous studies have not reached a consensus on the optimal ILM peeling size. Objectives: The objective of this study was to evaluate the outcomes of different ILM peeling sizes for idiopathic MHs. Methods: PubMed, Embase, Cochrane Library, Web of Science, CNKI, and WANFANG were searched until April 10, 2022. Studies in English or Chinese that compare the effects of two ILM peeling sizes (>2 disk diameters [DDs] vs. ≤2DD) for idiopathic MHs were included. The overall closure rate, postoperative best-corrected visual acuity (BCVA), type 1 closure, and adverse events were extracted. BCVA was converted to logarithm of the minimum angle of resolution (LogMAR). Results: Seven eligible studies (560 eyes) including 3 randomized clinical trials, 3 prospective trials, and one retrospective cohort were included. Pooled results showed a significantly better postoperative BCVA (mean difference = −0.16; 95% confidence interval [CI]: −0.27 to −0.04; LogMAR) and higher type 1 closure rate (risk ratio [RR] = 1.24; 95% CI: 1.08–1.43) in eyes with ILM peeling >2DD than those with peeling ≤2DD. No significant difference was found in overall closure rate and adverse events between the two groups. Subgroup analysis indicated that in MHs >400 μm, peeling >2DD helped obtain a better postoperative BCVA (mean difference = −0.17; 95% CI: −0.29 to −0.04; LogMAR) and higher frequency of type 1 closure (RR = 1.25; 95% CI: 1.03–1.51). Conclusions: Peeling >2DD shares similar safety level with peeling ≤2DD and has a superiority of facilitating visual recovery. Larger ILM peeling may be more beneficial for large MHs.

Publisher

S. Karger AG

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3