The paper presents experimental results on the effects of inlet total pressure distortion on the performance and flow field of a centrifugal compressor. The total pressure at the inlet is artificially distorted by means of a perforated sheet, which is supported by a support mesh. A total of eleven configurations, including clean inlet configuration, are tested. Performance measurements and impeller inlet and exit flow studies at three flow coefficients, one near design flow coefficient, one below design flow coefficient and one above design flow coefficient, are carried out. The present paper presents and discusses results at the three flow coefficients and the effects of stage loading on the distortion effects are presented. A new parameter, Distortion Index (DI) is introduced. As DI increases, the mass averaged total pressure at exit stations decreases. Distortion sector angle of 60° having the lowest total pressure is found to be the critical sector for circumferential distortion configurations. As the Distortion Correlation parameter, DC (60) increases, the mass averaged total pressure for circumferential distortion configuration decreases, except in the case of low flow coefficient where the mass averaged total pressure is nearly constant. DC (60) also increases with sector angle. The static pressure normalized with static pressure for clean inlet decreases as the distortion sector angle is increased. Distortion attenuates the static pressure as the flow passes through the vaneless diffuser. The attenuation increases with the distortion sector angle.
Reference29 articles.
1. Reuss, N. and Mundt, C., "Experimental Investigations of Pressure Distortions on the High Pressure Compressor Operating Behavior", AIAA Journal of Propulsion and Power, Vol.25, No.3, pp.653-667, 2009. 2. Ariga, I., Kasai, N., Masuda, S., Watanabe, Y. and Watanabe, I., "The Effect of Inlet Distortion on the Performance Characteristics of a Centrifugal Compressor", ASME Journal of Engineering for Power, Vol.105, No.2, pp.223-230, 1983. 3. Wright, T., Madhavan, S. and DiRe, J., "Centrifugal Fan Performance with Distorted Inflows", ASME Journal of Engineering for Gas Turbines and Power, Vol.106, No.4, pp.895-900, 1984. 4. Ariga, I., Masuda, S. and Ookita, S., "The Inducer Stall in a Centrifugal Compressor with Inlet Distortion", ASME Journal of Turbomachinery, Vol.109, No.1, pp.27-35, 1987. 5. Eisenlohr, G. and Benfer, F. W., "Auswirkungen von Einlaufstorungen auf das Betriebsverhalten eines Radialverichters", Motor. Zeits., Vol.47, pp.227-231, 1986.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|