Work of Breathing During Constant- and Variable-Flow Nasal Continuous Positive Airway Pressure in Preterm Neonates

Author:

Pandit Paresh B.12,Courtney Sherry E.23,Pyon Kee H.23,Saslow Judy G.23,Habib Robert H.4

Affiliation:

1. From the University of Medicine and Dentistry of New Jersey/Robert Wood Johnson Medical School, Camden, New Jersey;

2. Virtua-West Jersey Hospital, Voorhees, New Jersey;

3. Department of Pediatrics, Division of Neonatology, The Children's Regional Hospital at Cooper Hospital/UMC, Camden, New Jersey; and

4. Mercy Children's Hospital at St. Vincent Mercy Medical Center and Department of Pediatrics, Medical College of Ohio, Toledo, Ohio.

Abstract

Background. Constant-flow nasal continuous positive airway pressure (NCPAP) often is used in preterm neonates to recruit and maintain lung volume. Physical model studies indicate that a variable-flow NCPAP device provides more stable volume recruitment with less imposed work of breathing (WOB). Although superior lung recruitment with variable-flow NCPAP has been demonstrated in preterm neonates, corroborating WOB data are lacking. Objective. To measure and compare WOB associated with the use of variable-flow versus constant-flow NCPAP in preterm neonates. Methods. Twenty-four preterm infants who were receiving constant-flow NCPAP (means, SD) and had birth weight of 1024 ± 253 g, gestational age of 28 ± 1.7 weeks, age of 14 ± 13 days, and Fio2 of 0.3 ± 0.1 were studied. Variable-flow and constant-flow NCPAP were applied in random order. We measured changes in lung volume and tidal ventilation (VT) by DC-coupled/calibrated respiratory inductance plethysmography as well as esophageal pressures at NCPAP of 8, 6, 4, and 0 cm H2O. Inspiratory WOB (WOBI) and lung compliance were calculated from the esophageal pressure and VT data using standard methods. WOB was divided by VT to standardize the results. Results. WOBI decreased at all CPAP levels with variable-flow NCPAP, with a maximal decrease at 4 cm H2O. WOBI increased at all CPAP levels with constant-flow CPAP. Lung compliance increased at all NCPAP levels with variable-flow, with a relative decrease at 8 cm H2O, whereas it increased only at 8 cm H2O with constant-flow NCPAP. Compared with constant-flow NCPAP, WOBI was 13% to 29% lower with variable-flow NCPAP. Conclusion. WOBI is decreased with variable-flow NCPAP compared with constant-flow NCPAP. The increase in WOBI with constant-flow NCPAP indicates the presence of appreciable imposed WOB with this device. Our study, performed in neonates with little lung disease, indicates the possibility of lung overdistention at CPAP of 6 to 8 cm H2O with the variable-flow device. Further study is necessary to determine the efficacy of variable-flow NCPAP in neonates with significant lung disease and its use over extended periods of time.continuous-flow and variable-flow NCPAP, work of breathing, premature neonates, lung compliance.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology, and Child Health

Cited by 129 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3