Incidence and Outcome of CPAP Failure in Preterm Infants

Author:

Dargaville Peter A.12,Gerber Angela2,Johansson Stefan3,De Paoli Antonio G.2,Kamlin C. Omar F.456,Orsini Francesca7,Davis Peter G.456,

Affiliation:

1. Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia;

2. Department of Paediatrics, Royal Hobart Hospital, Hobart, Australia;

3. Clinical Epidemiology Unit, Department of Medicine, Solna, and Department of Clinical Science and Education, Södersjukhuset, Karolinska Institute, Stockholm, Sweden;

4. Neonatal Services, Royal Women’s Hospital, Melbourne, Australia;

5. Department of Obstetrics and Gynaecology, University of Melbourne, Melbourne, Australia;

6. Murdoch Children’s Research Institute, Melbourne, Australia; and

7. Clinical Epidemiology and Biostatistics Unit, Murdoch Children’s Research Institute, Melbourne, Australia

Abstract

BACKGROUND AND OBJECTIVES: Data from clinical trials support the use of continuous positive airway pressure (CPAP) for initial respiratory management in preterm infants, but there is concern regarding the potential failure of CPAP support. We aimed to examine the incidence and explore the outcomes of CPAP failure in Australian and New Zealand Neonatal Network data from 2007 to 2013. METHODS: Data from inborn preterm infants managed on CPAP from the outset were analyzed in 2 gestational age ranges (25–28 and 29–32 completed weeks). Outcomes after CPAP failure (need for intubation <72 hours) were compared with those succeeding on CPAP using adjusted odds ratios (AORs). RESULTS: Within the cohort of 19 103 infants, 11 684 were initially managed on CPAP. Failure of CPAP occurred in 863 (43%) of 1989 infants commencing on CPAP at 25–28 weeks’ gestation and 2061 (21%) of 9695 at 29–32 weeks. CPAP failure was associated with a substantially higher rate of pneumothorax, and a heightened risk of death, bronchopulmonary dysplasia (BPD) and other morbidities compared with those managed successfully on CPAP. The incidence of death or BPD was also increased: (25–28 weeks: 39% vs 20%, AOR 2.30, 99% confidence interval 1.71–3.10; 29–32 weeks: 12% vs 3.1%, AOR 3.62 [2.76–4.74]). The CPAP failure group had longer durations of respiratory support and hospitalization. CONCLUSIONS: CPAP failure in preterm infants is associated with increased risk of mortality and major morbidities, including BPD. Strategies to promote successful CPAP application should be pursued vigorously.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology, and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3