How Helpful Is Pneumatic Otoscopy in Improving Diagnostic Accuracy?

Author:

Jones Woodson S.12,Kaleida Phillip H.3

Affiliation:

1. Uniformed Services University, Bethesda, Maryland

2. San Antonio Military Pediatric Center, Lackland Air Force Base, Texas

3. University of Pittsburgh School of Medicine and Children’s Hospital of Pittsburgh, Pittsburgh, Pennsylvania

Abstract

Background. Pneumatic otoscopy is believed to be helpful in optimally assessing the presence or absence of middle ear effusion (MEE). Although expert clinicians teach the importance of this diagnostic skill to trainees, evidence exists that many pediatric providers do not typically perform pneumatic otoscopy. Objective. To determine if the otoscopic accuracy within a group of clinicians improves with the pneumatic assessment when compared with the static assessment using videotaped otoendoscopic examinations (VOEs). Methods. Residents and faculty from 2 pediatric training programs served as subjects. All viewed a set of 50 video otoscopic examinations of tympanic membranes (TMs) from a validated VOE developed previously for training purposes. The video displays each TM in a static presentation and then in a pneumatic (mobile) presentation, followed by a final static presentation. Each subject first viewed the initial static presentation of each TM and responded “yes/no” to the presence of MEE, and then viewed the pneumatic presentation of the same TM and again responded “yes/no” to the presence of MEE. We compared the accuracy of assessment for both the static and the pneumatic tests. Results. Thirty-four pediatric residents and 6 clinical faculty participated. Accuracy (percent of total test items correct) on the pneumatic test was uniformly greater than accuracy on the static test. The mean absolute improvement in the accuracy from the static test (61%) to the pneumatic test (76%) was 15% (95% confidence interval [CI] = 12%–18%). The mean relative improvement in accuracy from the static test to the pneumatic test was 26% (95% CI = 19%–32%). Higher accuracy on the VOE was associated with greater absolute (r = 0.57) and greater relative (r = 0.47) improvement. The mean relative improvement in sensitivity and specificity from static viewing to pneumatic viewing was 24% (95% CI = 15%–33%) and 42% (95% CI = 27%–58%), respectively. Conclusions. Using a video otoendoscopic test, we found that accurate identification of both the presence and the absence of MEE improved after pneumatic assessment of TM mobility. Providers who were more accurate at otoscopy, defined by higher video total test scores, benefited more from the pneumatic component than providers with lower scores.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology, and Child Health

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3