Affiliation:
1. Section of Neonatology, Department of Pediatrics, University of Colorado School of Medicine, Aurora, Co.
Abstract
Neonatal hyperglycemia is one of the most common metabolic abnormalities encountered in preterm and critically ill newborns. Although the definition varies, a blood glucose concentration greater than 125 mg/dL (6.9 mmol/L) or a plasma or serum glucose concentration greater than 150 mg/dL (8.3 mmol/L) often is used. Management of hyperglycemia is highly variable, probably because of the lack of evidence for improved outcomes in most neonates with any specific approach. This review focuses on the risk factors and causes for neonatal hyperglycemia, the associated consequences and pathology, and current management strategies.
Publisher
American Academy of Pediatrics (AAP)
Subject
Pediatrics, Perinatology, and Child Health
Reference39 articles.
1. Glucose extremes in newborn infants;Sunehag;Clin Perinatol,2002
2. Survey of the management of neonatal hyperglycaemia in Australasia;Alsweiler;J Paediatr Child Health.,2007
3. The continuous glucose monitoring sensor in neonatal intensive care;Beardsall;Arch Dis Child Fetal Neonatal Ed,2005
4. Continuous glucose monitoring in infants of very low birth weight;Iglesias;Neonatology,2009
5. Glucose intolerance in infants of very low birth weight. I. Incidence of hyperglycemia in infants of birth weights 1,100 grams or less;Dweck;Pediatrics,1974