Quantitative sensory testing cannot differentiate simulated sensory loss from sensory neuropathy

Author:

Freeman Roy,Chase Karen P.,Risk Marcelo R.

Abstract

Objective: To differentiate the quantitative sensory testing (QST) results of subjects simulating small and large fiber sensory loss from those of normal subjects and subjects with sensory peripheral neuropathy.Background: QST is used to measure sensory thresholds in clinical, epidemiologic, and research studies. It is not known whether there are objective test results that characterize the subject seeking to deceive the examiner.Methods: The Computer Aided Sensory Examination IV 4, 2, and 1 stepping algorithm was used to determine vibration and cold perception in nine naïve subjects. Subjects were asked to simulate sensory loss (on two occasions) and to respond normally on one occasion. Test results were compared to those of subjects with diabetic sensory neuropathy. Each QST trial was performed three times.Results: Reproducibility, measured by the intraclass correlation coefficient, was similar in all groups for the vibration perception test (simulation 1: 0.68 [95% CI 0.31, 0.91], simulation 2: 0.82 [95% CI 0.54, 0.95], normal response: 0.77 [95% CI 0.47, 0.94], and subjects with peripheral neuropathy: 0.76 [95% CI 0.18, 0.95]) and the cold perception test (simulation 1: 0.53 [95% CI 0.12, 0.85], simulation 2: 0.82 [95% CI 0.55, 0.95], normal subjects: 0.67 [95% CI 0.30, 0.90] and subjects with peripheral neuropathy: 0.88 [95% CI 0.57, 0.97]), all just noticeable difference units. There were no differences between performance characteristics in the two simulation trials. Responses to null stimuli did not differentiate between groups.Conclusion: Test performance characteristics do not permit discrimination among subjects simulating sensory loss, subjects with normal responses, and subjects with peripheral neuropathy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical)

Reference14 articles.

1. Quantitative Sensory Testing

2. Quantitative sensory testing

3. Stewart JD, Freeman R. Quantitative sensory testing. In: Brown WF, Bolton CF, Aminoff MJ, eds. Neuromuscular function and disease. Philadelphia: WB Saunders, 2002; 131–144.

4. Limitations of quantitative sensory testing when patients are biased toward a bad outcome

5. Variance of sensory threshold measurements: Discrimination of feigners from trustworthy performers

Cited by 86 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3