Affiliation:
1. Technological Design Institute of Scientific Instrument Engineering SB RAS
Abstract
A theoretical analysis of the image-forming properties of the conical axicon in the scalar diffraction Kirchhoff-Fresnel approximation within the framework of the theory of linear systems revealed that the classical concept of the point spread function is not applicable to axicon images. In the near diffraction zone, a point light source is imaging by a conical axicon in the form of a segment along a straight line connecting the source and the center of the axicon. Moreover, different annular areas of the axicon form different sections on this segment. When used in tandem with a lens, the axicon can allow to increase the depth of focus. Preliminary experimental data have been obtained, which confirm the theoretical conclusions.
Publisher
Siberian State University of Geosystems and Technologies
Subject
Industrial and Manufacturing Engineering