Affiliation:
1. MARMARA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, DİŞ HEKİMLİĞİ PR.
2. MARMARA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
Abstract
Objective: Novel strength-gradient monolithic zirconia is a developed material recently introduced to the market and its mechanical properties should be investigated in vitro. The aim of the study is to compare the wear rates of three different CAD/CAM materials with a chewing simulator after one year of dynamic loading.
Methods: 7x7x3 mm discs were prepared from lithium disilicate, strength-gradient monolithic zirconia, and zirconia-reinforced lithium silicate glass ceramic. Both groups were divided into two subgroups (n=12) as glazed and mechanically polished.
The samples were scanned with a laser scanner device (SD Mechatronic Laser Scanner LAS-20, Westerham, Germany) to determine the amount of wear. The samples were placed in a chewing simulator (SD Mechatronic Chewing Simulator CS-4.2, Westerham, Germany) for 240 000 cycles which is equivalent to 1 year of clinical use. After the dynamic loading in the chewing simulator, the samples were scanned again in the laser scanner, and the data was obtained. Kruskal Wallis test was used to analyze the data.
Results: The amount of wear of each material was found to be statistically significant (p< .05). No significant differences between the polished and glazed groups of Zir and LD were found but glazed CD was significantly more wear-resistant than polished CD (p< .05).
Conclusions: Wear is a phenomenon that can be affected by different factors such as microstructure and surface finishing of the materials. Wear resistance should be taken into consideration when choosing a material.