Abstract

Introduction. Dental implantation is getting more popular with patients who require total dental rehabilitation. Patients note that possibility of immediate loading based on dental implants is more favorable treatment option due to active social life. Low bone density, often occurred in the maxilla, frequently presents challenges for clinicians to achieve successful implant primary stability for predictable immediate loading.The aim of our study was to increase the efficiency of treatment of patients who require dental implantation in the maxilla.Materials and methods. Twenty-seven patients aged from 27 to 66 years with missing teeth in the alveolar process of maxilla were treated. All patients in this randomized clinical trial were divided into two groups. We used two methods for implant site preparation: the standard technique according to manufacturer’s recommendations in the first group (n = 13) and the Osseodensification technique via Densah drills (n = 14) in the second. All patients were treated by Astra Tech dental implants with the same dimensions (diameter 4 mm, length 9 mm). Immediately after implant placement the data of the frequency-resonance analysis of the implant stability and insertion torque were installed and obtained. Furthermore, a comparison of the operation time was carried out. Clinical evaluation and patient appreciation of pain, edema and hyperemia of the mucosa were evaluated using a questionnaire at 1, 3, 5 and 7 days after surgery. The measurement of the values of the stability quotient of the implants was repeated and carried out after six months.Results. Higher values of implant primary stability (insertion torque and implant stability quotient during surgery) were showed in the osseodensification group (IT — (45,0±5,8), ISQ — (71,8±2,9)) in comparison with standard technique (IT — (27,7±3,8), ISQ — (62,8±3,2)); p < 0,05.Discussion. Osseodensification technique promotes compaction of a low density bone in direct contact with the implant, which leads to higher implant primary stability due to the physical interaction between bone and implant.Conclusion. The obtained results allow us to consider that the osseodensification method is progressive for improving the effectiveness of implantological treatment on maxilla.

Publisher

Ural State Medical University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3