Abstract

Relevance. Currently, the stability of various options for the fixation of sacral fractures by the finite element method has not been sufficiently studied.Purpose — the biomechanical characteristics of two variants of internal fixation of unilateral sacral fractures by various implants and the localization of the line of its fracture with respect to the articular facet of the L5-S1 vertebrae were studied.Materials and Methods. Using the finite element method, we studied the biomechanical characteristics of two options for fixing a one-sided longitudinal fracture of the sacrum with different localization of the line of its fracture: outside, inside and directly on the joint facet L5-S1. Two fixation options are considered: cannulated sacroiliac screws and a similar option in combination with a bilateral lumbar-pelvic transpedicular system.Results. The stresses in implants and bone under compression load and torso forward or backward are almost the same in all models. In the model of fixation with a sacroiliac screw of a one-sided longitudinal sacral fracture, the line of which passes through the articular process S1 of the vertebra (Isler II type), the greatest stress in the screws under compression load and bending moment was 619.7 MPa, which exceeds the yield strength of the titanium alloy and can damage the implants. In all models where the transpedicular system additionally acted as fixing structures, a decrease of 42–77% of maximum displacements was noted, by 28–79% of equivalent stresses in implants under all types of loads, while the equivalent stresses in the bone structures did not differ significantly. In models where the transpedicular system was additionally applied, a decrease of 42–77% of maximum displacements was noted, by 28-79% of stresses in implants under all types of loads, while the stresses in the bones did not differ much.Conclusion. In all cases of localization of the line of unilateral fracture of the sacrum, the use of a transpedicular system in combination with sacroiliac screws is more stable from the point of view of biomechanics. The most unstable is a one-sided longitudinal fracture of the sacrum passing through the facet L5-S1.

Publisher

ECO-Vector LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Leonid Yu. Kossovich. To the 75th birthday anniversary;Izvestiya of Saratov University. Mathematics. Mechanics. Informatics;2024-02-20

2. Using the Mask-RCNN Convolutional Neural Network to Automate the Construction of Two-Dimensional Solid Vertebral Models;Izvestiya of Saratov University. New Series. Series: Mathematics. Mechanics. Informatics;2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3