Outcomes Associated With Extraction Versus Capping and Abandoning Pacing and Defibrillator Leads

Author:

Pokorney Sean D.1,Mi Xiaojuan1,Lewis Robert K.1,Greiner Melissa1,Epstein Laurence M.1,Carrillo Roger G.1,Zeitler Emily P.1,Al-Khatib Sana M.1,Hegland Donald D.1,Piccini Jonathan P.1

Affiliation:

1. From Duke University Medical Center, Durham, NC (S.D.P., R.K.L., E.P.Z., S.M.A.-K., D.D.H., J.P.P.); Duke Clinical Research Institute, Durham, NC (S.D.P., X.M., M.G., E.P.Z., S.M.A.-K., J.P.P.); Brigham and Women’s Hospital, Boston, MA (L.M.E.); and University of Miami, FL (R.G.C.).

Abstract

Background: Lead management is an increasingly important aspect of care in patients with cardiac implantable electronic devices; however, relatively little is known about long-term outcomes after capping and abandoning leads. Methods: Using the 5% Medicare sample, we identified patients with de novo cardiac implantable electronic device implantations between January 1, 2000, and December 31, 2013, and with a subsequent lead addition or extraction ≥12 months after the de novo implantation. Patients who underwent extraction for infection were excluded. Using multivariable Cox proportional hazards models, we compared cumulative incidence of all-cause mortality, device-related infection, device revision, and lead extraction at 1 and 5 years for the extraction versus the cap and abandon group. Results: Among 6859 patients, 1113 (16.2%) underwent extraction, whereas 5746 (83.8%) underwent capping and abandonment. Extraction patients tended to be younger (median, 78 versus 79 years; P <0.0001), were less likely to be male (65% versus 68%; P =0.05), and had shorter lead dwell time (median, 3.0 versus 4.0 years; P <0.0001) and fewer comorbidities. Over a median follow-up of 2.4 years (25th, 75th percentiles, 1.0, 4.3 years), the overall 1-year and 5-year cumulative incidence of mortality was 13.5% (95% confidence interval [CI], 12.7–14.4) and 54.3% (95% CI, 52.8–55.8), respectively. Extraction was associated with a lower risk of device infection at 5 years relative to capping (adjusted hazard ratio, 0.78; 95% CI, 0.62–0.97; P =0.027). There was no association between extraction and mortality, lead revision, or lead extraction at 5 years. Conclusions: Elective lead extraction for noninfectious indications had similar long-term survival to that for capping and abandoning leads in a Medicare population. However, extraction was associated with lower risk of device infections at 5 years.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 60 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3