Abstract

Background— In patients with percutaneous device implantation for closure of patent foramen ovale (PFO), a 10% incidence of new or worsened aortic regurgitation within 12 months has been reported with echocardiography. Cardiac magnetic resonance imaging is a powerful noninvasive tool to quantify volume and fraction of valve insufficiencies. We studied the acute and long-term impact of percutaneous device implantation for PFO closure on valve insufficiencies in cardiac magnetic resonance imaging. Methods and Results— Sequential cardiac magnetic resonance imaging studies were performed in 102 patients with cryptogenic ischemic events. Cardiac magnetic resonance imaging was performed before PFO closure, the day after device implantation, and at 12 months of follow-up. There was no difference in volumetric and hemodynamic parameters before PFO closure compared with 12 months of follow-up. With a cutoff for relevant regurgitation fraction of 5%, there were no statistically significant differences in regurgitation fraction of the semilunar and atrioventricular valves. The median fraction of aortic valve insufficiency was 3.9% (interquartile range [IQR] 2.0% to 5.1%) before PFO closure, 5.4% (IQR 4.1% to 5.9%) after device implantation, and 4.3% (IQR 3.3% to 6.0%) at 12 months of follow-up. The size and type of the occluder had no impact on aortic valve insufficiency. Median regurgitation fraction for the pulmonary valve was 3.6% (IQR 2.4% to 6.7%) before intervention, 7.3% (IQR 5.1% to 8.2%) after occluder implantation and 5.8% (IQR 4.8% to 7.4%) at 12 months of follow-up. Values for the mitral valve were 3.1% (IQR 1.4% to 6.0%), 5.5% (IQR 3.5% to 7.3%), and 3.8% (IQR 1.5% to 7.9%) and for the tricuspid valve were 5.4% (IQR 0.1% to 8.8%), 5.8% (IQR 1.4% to 9.2%), and 6.0% (IQR 1.1% to 8.4%), respectively. Conclusions— Percutaneous PFO closure with device implantation has no impact on valve insufficiencies as determined by cardiac magnetic resonance imaging.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3