Six-Month Clinical and Angiographic Outcome of the New, Less Shortening Wallstent in Native Coronary Arteries

Author:

Ozaki Yukio1,Keane David1,Ruygrok Peter1,van der Giessen Willem J.1,de Feyter Pim1,Serruys Patrick W.1

Affiliation:

1. From the Catheterization Laboratory, Thoraxcenter, Erasmus University, Rotterdam, Netherlands.

Abstract

Background The new, less shortening, self-expanding Wallstent is characterized by longitudinal flexibility, a protective membrane, a low profile, and a customized range of diameters (3.5 to 6.0 mm). The recent modification of the braiding angle of the Wallstent has resulted in a new device with less shortening on expansion and a concomitant reduction in radial force. We hypothesized that the enforced mechanical remodeling produced by the selection of an oversized Wallstent might result in improved accommodation of subsequent reactive intimal hyperplasia and prevention of chronic recoil of the vessel. Methods and Results To prove this hypothesis, we recently implanted 44 new, less shortening Wallstents in 35 native coronary arteries in 35 patients with acute or threatened closure after balloon angioplasty, according to a strategy of oversizing of Wallstent diameter and complete coverage of the lesion length. The initial and 6-month follow-up angiograms were analyzed with a computer-based quantitative coronary angiography (QCA) system. Acute gain (minimal luminal diameter [MLD] post minus MLD pre) and late loss (MLD post minus MLD at follow-up) were examined. Stent deployment was successful in 44 of 44 attempts (100%). Nominal stent diameter used was 1.40 mm larger than the maximal vessel diameter. One patient (3%) with a dilated but unstented lesion proximal to the stented segment sustained a subacute occlusion on day 1 associated with myocardial infarction. Event-free survival at 30 days after stent implantation was 97% (34 of 35 patients). Of the 34 patients eligible for 6-month angiographic follow-up, 3 who were asymptomatic declined repeat angiography. MLD (and percent diameter stenosis [% DS]) changed from 0.83±0.50 mm (72%) pre through 3.06±0.48 mm (15%) post to 2.27±0.74 mm (28%) at follow-up. Acute gain was 2.23±0.63 mm, and late loss was 0.78±0.61 mm. Angiographic restenosis (>50% DS) was observed in 5 of 31 patients (16%) at 6 months, all of whom underwent repeat angioplasty. Thus, the overall event-free survival at 6-month follow-up was 83% (29 of 35 patients). Conclusions The oversized Wallstent implantation with complete coverage of the lesion length conveyed a favorable 6-month clinical and angiographic outcome. The large acute gain obtained by the Wallstent afforded greater accommodation of the subsequent late loss. The enforced mechanical remodeling by oversized new Wallstents may result in prevention of acute and chronic recoil of the vessel wall and subsequently a lower restenosis rate at follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3