The Power-Velocity Integral at the Vena Contracta

Author:

Buck Thomas1,Mucci Ronald A.1,Guerrero J. Luis1,Holmvang Godtfred1,Handschumacher Mark D.1,Levine Robert A.1

Affiliation:

1. From the Cardiac Ultrasound Laboratory (T.B., R.A.M., M.D.H., R.A.L.), Cardiovascular Surgical Unit (J.L.G.), and Cardiac MRI Unit (G.H.), Massachusetts General Hospital, Harvard Medical School, Boston.

Abstract

Background —Noninvasive quantification of regurgitation is limited because Doppler measures velocity, not flow. Because backscattered Doppler power is proportional to sonified blood volume, power times velocity should be proportional to flow rate. Early studies, however, suggested that this held only for laminar flow, not for regurgitant jets, in which turbulence and fluid entrainment augment scatter. We therefore hypothesized that this Doppler power principle can be applied at the proximal vena contracta, where flow is laminar before entrainment, so that the power-times-velocity integral should vary linearly with flow rate and its time integral with stroke volume (SV). Methods and Results —This was tested in vitro with steady and pulsatile flow through 0.07- to 0.8-cm 2 orifices and in 36 hemodynamic stages in vivo, replacing the left atrium with a rigid chamber and column for direct visual recording of mitral regurgitant SV (MRSV). In 12 patients, MRSV was compared with MRI mitral inflow minus aortic outflow and in 11 patients with 3D echo left ventricular ejection volume–Doppler aortic forward SV. Vena contracta power in the narrow high-velocity spectrum from a broad measuring beam was calibrated against that from a narrow reference beam of known area. Calculated and actual flow rates and SV correlated well in vitro ( r =0.99, 0.99; error=−1.6±2.5 mL/s, −2.4±2.9 mL), in vivo (MRSV: r =0.98, error=0.04±0.87 mL), and in patients (MRSV: r =0.98, error=−2.8±4.5 mL). Conclusions —The power-velocity integral at the vena contracta provides an accurate direct measurement of regurgitant flow, overcoming the limitations of existing Doppler techniques.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3