Automatic Online Embolus Detection and Artifact Rejection With the First Multifrequency Transcranial Doppler

Author:

Brucher Rainer1,Russell David1

Affiliation:

1. From the Department of Medical Engineering (R.B.), University of Applied Sciences, Ulm, Germany, and the Department of Neurology (D.R.), The National Hospital, Oslo, Norway.

Abstract

Background and Purpose The goal of this study was to assess the first multifrequency transcranial Doppler system specially developed for online automatic detection of cerebral microemboli. Methods The multifrequency Doppler instrumentation insonates simultaneously with 2.0- and 2.5-MHz frequencies. The detection threshold for embolus detection used in this study was a relative Doppler energy increase of >20 dB · ms, at which point the Doppler power increase was at least 5 dB and lasted >4 ms above the background energy. Four parameters were used in an optimized binary decision tree to recognize emboli: quarter Doppler shift, maximum duration limit, reference gate, and bidirectional enhancement. In in vitro studies, 200 plastic microspheres (80 μm), 200 gas bubbles (8 to 25 μm), and 600 artifacts were studied in a pulsatile closed-loop system. In vivo studies were carried out for 1 hour in 15 patients with mechanical heart valves and in 45 patients with carotid stenosis. This gave a total of 60 hours of online automatic monitoring in patients. Results All 400 plastic spheres and microbubbles were automatically detected and correctly classified. Of the 600 artifacts, 596 (99.3%) were correctly classified as artifacts, and 4 (0.7%) were incorrectly identified as emboli (κ=0.992, P <0.001). The experienced observer detected a total of 554 emboli and 800 artifacts in the heart valve (521 emboli, 400 artifacts) and carotid stenosis (33 emboli, 400 artifacts) patients. With multifrequency Doppler, 546 of these emboli (98.6%) and 791 of these artifacts (98.9%) were automatically detected and correctly classified as embolus or artifact (κ=0.953, P <0.0001). Conclusions We found that multifrequency transcranial Doppler had a relatively high sensitivity and specificity when used to automatically detect cerebral microemboli and reject artifacts online.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3