Changes Over Time in Optimal Duplex Threshold for the Identification of Patients Eligible for Carotid Endarterectomy

Author:

Elgersma Otto E. H.1,van Leersum Marc1,Buijs Pieter C.1,van Leeuwen Maarten S.1,van de Schouw Yvonne T.1,Eikelboom Bert C.1,van der Graaf Yolanda1

Affiliation:

1. From the Department of Radiology (O.E.H.E., P.C.B., M. van L., M.S. van L.), the Department of Vascular Surgery (B.C.E.), and the Julius Center for Patient Oriented Research (O.E.H.E., Y.T. van de S., Y. van der G.), University Hospital Utrecht (Netherlands).

Abstract

Background and Purpose —Two surgical trials established that carotid endarterectomy is beneficial to symptomatic patients who have a severe internal carotid artery (ICA) stenosis on angiograms. Duplex ultrasonography–derived hemodynamic parameters show a good correlation with angiography and are often used for detecting severe ICA stenoses. However, duplex performance is ultrasound machine and operator dependent. Over time both may change, possibly affecting duplex performance. We compared duplex performance of 2 time periods in 1 specific vascular laboratory using angiography as the gold standard. Methods —Consecutive patients who underwent both angiography and duplex examinations of the ICA were evaluated (first period, 60 patients; second period, 61 patients). Peak systolic velocity and several other hemodynamic parameters and ratios were analyzed by receiver operating characteristic curves in their ability to detect severe ICA stenoses. The optimal parameter and threshold were determined for each period. Subsequently, duplex test characteristics were compared after the optimal thresholds of both the first and the second periods were applied in the second period. Results —In both periods peak systolic velocity of the ICA was the best test parameter; areas under the receiver operating characteristic curve were similar (0.957 and 0.954, respectively). However, the optimal threshold was different. The optimal threshold in the second period was 270 cm/s. When the optimal threshold of 210 cm/s of the first period was applied in the second period, test characteristics changed significantly. Sensitivity increased from 98% to 100%, and specificity decreased from 85% to 71% ( P =0.004). Conclusions —The optimal threshold for detecting severe ICA stenoses with duplex ultrasonography in our laboratory changed over time. Individual laboratories should assess duplex accuracy regularly and adjust adopted criteria if necessary to keep diagnostic performance optimal.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 53 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3