Computed Tomographic Angiography for the Evaluation of Carotid Artery Stenosis

Author:

Leclerc X.1,Godefroy O.1,Pruvo J. P.1,Leys D.1

Affiliation:

1. From the Departments of Radiology (X.L., J.P.P.) and Neurology (O.G., D.L.), University Hospital of Lille (France).

Abstract

Background and Purpose No previous study has compared the reliability of carotid artery measurement provided by axial images, shaded surface display (SSD), and maximum intensity projection (MIP). Methods Helical CT and conventional angiography were performed prospectively in 20 patients with atherosclerotic stenosis of the internal carotid artery. Stenosis measurement was performed in a blinded fashion on angiography and CT by two independent examiners. Calcifications were segmented when they were located far enough from the vascular lumen. SSD and MIP were systematically performed for each carotid bifurcation. We measured stenosis using conventional angiography as standard and the different CT reconstructions (axial images, SSD, and MIP) by comparing the stenosis diameter at its narrowest point to the normal internal carotid artery. The degree of stenosis was classified into six groups: no stenosis, mild stenosis (<30%), moderate stenosis (30% to 70%), severe stenosis (>70%), near occlusion, and occlusion (100%). No measurement was made in cases of normal artery, near occlusion, and occlusion. Results Correlations between angiography and the three types of reconstruction were very good. Axial sections correctly classified the carotid arteries in 95% of cases. In 10 carotid arteries, stenosis was not assessable by SSD and MIP because of calcifications. In the remaining carotid arteries, MIP correctly classified the degree of stenosis in 96% of cases, whereas SSD misclassified 21% of cases. Conclusions Our study showed that axial images provide a reliable evaluation of carotid artery stenosis. Calcifications are limiting factors in SSD or MIP. When atherosclerotic plaques are not calcified, MIP reconstructions provide a more reliable measurement of the vascular lumen than SSD.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 90 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3