Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves.

Author:

Georgiadis D1,Grosset D G1,Kelman A1,Faichney A1,Lees K R1

Affiliation:

1. University Department of Medicine, Western Infirmary, Glasgow, UK.

Abstract

Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in three groups of patients with different prosthetic valves. One hundred seventy-nine patients with prosthetic cardiac valves (85 Björk-Shiley, 56 Medtronic-Hall, and 38 Carpentier-Edwards) and 25 normal subjects were examined using transcranial Doppler. Monitoring time was 30 minutes over the right middle cerebral artery. The prevalence and numbers of embolic signals were significantly higher in patients with Björk-Shiley compared with those with Medtronic-Hall and Carpentier-Edwards valves (89% versus 50% and 53%, respectively; P < .001, chi 2; 156 [112, 204] versus 2 [1, 4] and 2 [1, 4] signals/h, respectively; median [95% nonparametric confidence interval], both P < .001, multiple comparisons, Bonferroni correction). The signal intensity was significantly higher in patients with Björk-Shiley and Medtronic-Hall valves than patients with Carpentier-Edwards valves (2435 [2345, 2527] and 2120 [1745, 2483] versus 225 [184, 287] power units, median [95% confidence interval], both P < .001). No correlation was found between embolic signal numbers and clinical parameters including history of neurological deficit, cardiac rhythm, duration of artificial valve, previous cardiac operations, or intensity of anticoagulation. Embolic signals were not detected in any of the control subjects. Our data showed that the prevalence, quantity, and acoustic characteristics of Doppler embolic signals differ in patients having three different types of prosthetic heart valves. However, no correlation with clinical parameters was identified.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Reference28 articles.

1. Spencer MP Campbell SD Sealy JL Henry FC Lindbergh J. Experiments on decompression bubbles in the circulation using ultrasonic and electromagnetic flowmeters. / Occup Med. 1969;11: 238-247.

2. Microemboli detection in stroke associated with atrial fibrillation;Tegeler CH;J Cardiovasc Technol.,1990

3. Carotid emboli predict poor outcome in stroke;Tegeler CH;Stroke.,1993

4. Detection of microemboli in patients with artificial heart valves using transcranial Doppler: preliminary observations;Rams JJ;J Heart Valve Dis.,1993

5. Detection of intracranial emboli in patients with symptomatic extracranial carotid artery disease.

Cited by 116 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3