Preoperative Assessment of the Carotid Bifurcation

Author:

Patel Mahesh R.1,Kuntz Karen M.1,Klufas Roman A.1,Kim Ducksoo1,Kramer Jonathan1,Polak Joseph F.1,Skillman John J.1,Whittemore Anthony D.1,Edelman Robert R.1,Kent K. Craig1

Affiliation:

1. From the Departments of Radiology (M.R.P., D.K., J.K., R.R.E.) and Surgery (K.C.K., J.J.S.), Beth Israel Hospital, and the Departments of Medicine (K.M.K.), Radiology (R.A.K., J.F.P.), and Surgery (A.D.W.), Brigham and Women’s Hospital, Harvard Medical School, Boston, Mass.

Abstract

Background and Purpose Noninvasive studies are used with increasing frequency to assess the carotid bifurcation before endarterectomy. Therefore, assessment of their diagnostic accuracies is essential for appropriate patient management. We prospectively evaluate two noninvasive tests, magnetic resonance angiography (MRA) and duplex ultrasonography (DU), as potential replacements for contrast arteriography (CA). Methods A blinded comparison of three-dimensional time-of-flight (TOF) MRA, two-dimensional TOF MRA, and DU in 176 arteries was performed. CA was used as the standard of comparison. Results Three-dimensional TOF MRA had a sensitivity of 94%, a specificity of 85%, and an accuracy of 88% for the identification of 70% to 99% stenosis; two-dimensional TOF MRA had a sensitivity and specificity that were approximately 10% lower than those of three-dimensional TOF MRA. DU resulted in a sensitivity of 94%, a specificity of 83%, and an accuracy of 86%. Combining data from three-dimensional TOF MRA and DU, allowing for CA only for disparate results, yielded a sensitivity of 100%, a specificity of 91%, and an accuracy of 94% among concordant noninvasive tests, with CA required in 16% of arteries. MRA accurately differentiated 17 carotid occlusions from 16 high-grade (90% to 99%) stenoses, whereas with DU two patent arteries were identified as occluded and one occluded artery was identified as patent. Conclusions Three-dimensional TOF MRA is the most accurate noninvasive test. Combined use of MRA and DU results in a marked increase in accuracy to a level that obviates the need for CA in a majority of patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 176 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments;Cochrane Database of Systematic Reviews;2022-07-11

2. Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments;COCHRANE DB SYST REV;2022

3. Color Duplex Scanning of the Extracranial Carotid Arteries;Noninvasive Vascular Diagnosis;2022

4. The carotid axis revisited;Scientific Reports;2021-07-05

5. CT and MR Angiography of the Brain and Carotid Arteries;Medical Imaging Contrast Agents: A Clinical Manual;2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3