Reliability of Longitudinal Ultrasonographic Measurements of Carotid Intimal-Medial Thicknesses

Author:

Espeland Mark A.1,Craven Timothy E.1,Riley Ward A.1,Corson John1,Romont Alicia1,Furberg Curt D.1

Affiliation:

1. From the Departments of Public Health Sciences (M.A.E., T.E.C., W.A.R., C.D.F.) and Neurology (W.A.R.), Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, NC; and the Section of Vascular Surgery (J.C.) and the Division of Cerebrovascular Diseases (A.R.), University of Iowa College of Medicine (Iowa City).

Abstract

Background and Purpose Serial ultrasonic B-mode measurements of intimal-medial thickness (IMT) of the carotid artery are commonly used as surrogates for describing atherosclerosis progression. This report describes the longitudinal reliability of IMT measurement during a multicenter clinical trial, quantifies the error attributable to differences among readers, and discusses how studies can be efficiently designed. Methods Serial B-mode measurements of carotid IMT from the 3-year Asymptomatic Carotid Artery Progression Study (ACAPS; formerly Asymptomatic Carotid Artery Plaque Study) were used to estimate the contributions to longitudinal measurement error of systematic reader effects, nonvisualization, and nonsystematic error and to describe the distribution of “true” progression rates that underlie the observed data. Variance components were estimated from random-effects models fitted to outcome measures formed by averaging IMTs from different sets of carotid artery walls. These were used to contrast the relative efficiency of study designs. Results Of the total variance of measured IMT, 11% was attributable to systematic differences among readers. Nonvisualization contributed less than 7%. Thus, the predominant source of error was unaccounted for (ie, random error or “noise,” which in our analyses included any drift, nonlinearity, and sonographer differences). For studies with measurement protocols similar to ACAPS, follow-up times of 2 years or more are desirable for describing the mean progression rates of cohorts, and of 6 years or more for categorizing progression within individuals. In 3-year studies, sample sizes as low as 237 provide 90% statistical power for detecting risk factors that have correlations with IMT progression of .50 or greater. Conclusions The ACAPS measurement protocol provided highly reliable serial IMT data. Moderate-sized multicenter studies using B-mode outcomes are feasible.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 109 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3