Transoccipital Power-Based Color-Coded Duplex Sonography of Cerebral Sinuses and Veins

Author:

Baumgartner Ralf W.1,Nirkko Arto C.1,Müri René M.1,Gönner Friedrich1

Affiliation:

1. From the Department of Neurology, Inselspital, University of Bern (Switzerland).

Abstract

Background and Purpose Power-based transcranial color-coded duplex sonography is a new development for cerebrovascular imaging that is suited for detection of slow velocities. The purpose of this study was to evaluate the ability of this technique to detect cerebral sinuses and veins by means of the occipital window and to provide reference data. Methods The straight and inferior sagittal sinuses, great and internal cerebral veins, and basal veins were insonated in 120 normal subjects. The number of identified vessels, peak systolic (PSV) and end-diastolic (PDV) velocities, and resistance indices were determined. Results In subjects aged 20 to 59 years, straight sinuses were identified in 81% and great and internal cerebral veins in 34%. In subjects aged 60 to 79 years, straight sinuses were detected in 50%, great cerebral veins in 20%, and internal cerebral veins in 13%. All insonated inferior sagittal sinuses and basal veins were missed. Velocities were highest in straight sinuses (PSV, 35 [7 to 64] cm/s; PDV, 23 [2 to 43] cm/s), slower in great cerebral veins (PSV, 23 [12 to 34] cm/s; PDV, 16 [7 to 26] cm/s), and slowest in internal cerebral veins (PSV, 14 [10 to 18] cm/s; PDV, 10 [5 to 15] cm/s) (mean with 95% confidence intervals [CIs]). Straight sinus velocities decreased with age for PSV (20 to 39 years, 40 [7 to 73] cm/s; 60 to 79 years, 28 [9 to 46] cm/s; P <.01) and PDV values (20 to 39 years, 28 [4 to 52] cm/s; 60 to 79 years, 16 [5 to 26] cm/s; P <.001) (mean with 95% CIs) and were higher in women than men in the group aged 20 to 39 years. ( P <.05). Resistance indices increased with age in the straight sinus (20 to 39 years, 0.30 [0.18 to 0.42]; 60 to 79 years, 0.42 [0.31 to 0.53]; P <.001) (mean with 95% CIs). Conclusions Transoccipital power-based color-coded duplex sonography enabled imaging and velocity measurements in the straight sinus of subjects aged 20 to 59 years. In elder subjects detection rate of the straight sinus decreased, and it was low for deep cerebral veins in all age groups.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 50 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3