Accuracy and Prognostic Consequences of Ultrasonography in Identifying Severe Carotid Artery Stenosis

Author:

Eliasziw M.1,Rankin R.N.1,Fox A.J.1,Haynes R.B.1,Barnett H.J.M.1

Affiliation:

1. From the Departments of Epidemiology and Biostatistics (M.E.), Clinical Neurological Sciences (M.E., A.J.F., H.J.M.B.), and Diagnostic Radiology (R.N.R., A.J.F.), University of Western Ontario; The John P. Robarts Research Institute (M.E., H.J.M.B.), London, Ontario; and the Departments of Clinical Epidemiology and Biostatistics and of Medicine, McMaster University, Hamilton, Ontario (R.B.H.), Canada.

Abstract

Background and Purpose The accuracy of routine ultrasonography in detecting severe carotid artery stenosis was evaluated in comparison with cerebral angiography. The precision of ultrasonographic criteria in predicting the risk of stroke was also assessed. Methods A total of 1011 symptomatic carotid bifurcations were studied in patients from the North American Symptomatic Carotid Endarterectomy Trial (NASCET). Given that all patients were considered for entry into the trial, the chance of a verification bias affecting the analyses was minimized. The ultrasonographic data consisted of peak systolic velocities and frequency changes from both the internal and common carotid arteries. Angiographic stenosis was calculated as in NASCET. Receiver operating characteristic (ROC) curves were constructed from the ultrasonographic data for the detection of 70% or greater stenosis on the basis of an angiographic assessment. Kaplan-Meier stroke-free survival curves were used to predict the risk of stroke. Results The areas under the ROC curves ranged from 0.74 to 0.75 (95% confidence interval [CI], 0.69 to 0.79). The sensitivities and specificities ranged from 0.65 to 0.71. The risk of stroke at 18 months declined sharply as the degree of angiographically defined stenosis declined from 99% to 70%. No pattern of decline was apparent on the basis of the ultrasonographic data. Conclusions The results indicate that the accuracy of ultrasonography is moderate when flow parameters are used to assess the degree of stenosis. Ultrasonography should be used as a screening tool to exclude patients with no carotid artery disease from further testing. Conventional angiography remains an essential investigation before assigning the risk of stroke and deciding appropriate treatment for extracranial carotid artery disease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3