Intentional Fracture of Maximally Dilated Balloon-Expandable Pulmonary Artery Stents Using Ultra–High-Pressure Balloon Angioplasty

Author:

Morray Brian H.1,McElhinney Doff B.1,Marshall Audrey C.1,Porras Diego1

Affiliation:

1. From the Department of Pediatrics, Seattle Children’s Hospital, WA (B.H.M.); Department of Cardiothoracic Surgery, Lucille Packard Children’s Hospital at Stanford, Palo Alto, CA (D.B.M.); and Department of Cardiology, Boston Children’s Hospital, Boston, MA (A.C.M., D.P.).

Abstract

Background— Treatment with endovascular stents has become increasingly common for the management of vascular stenosis in congenital heart disease. The use of stents in smaller patients has been tempered by concerns about the potential for stent expansion to accommodate somatic growth. One solution to limited stent diameter is the intentional fracture of maximally dilated stents, which can be accomplished using ultra–high-pressure (UHP) balloons. Methods and Results— This retrospective cohort study compared procedural characteristics and adverse events between a cohort of patients with branch pulmonary artery (PA) stents who underwent stent fracture using UHP balloons and control patients who underwent UHP redilation of previously placed PA stents without stent fracture between 2004 and 2014. Two control patients were selected for every case. Thirty-three PA stents were fractured in 31 patients with a median of 10 years after initial stent placement. The median balloon:waist ratio was 1.17 (1–1.71), and the median inflation pressure was 20 (8–30) atm. There were significant reductions in pressure gradient after angioplasty, with no difference in postangioplasty gradients between cases and controls. There were no major PA complications in the stent fracture group and no difference in the number of adverse events between the 2 groups. Conclusions— In this small series, PA stent fracture using UHP balloon angioplasty was feasible and did not result in major complications although predictors of successful fracture were not identified. Intentional fracture with UHP balloon angioplasty may be considered when treating stents that have become restrictive despite maximal dilation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3