Prediction of Cardiac Resynchronization Therapy Response

Author:

Bertini Matteo1,Delgado Victoria1,den Uijl Dennis W.1,Nucifora Gaetano1,Ng Arnold C.T.1,van Bommel Rutger J.1,Borleffs C. Jan Willem1,Boriani Giuseppe1,Schalij Martin J.1,Bax Jeroen J.1

Affiliation:

1. From the Department of Cardiology (M.B., V.D., D.W.d.U., G.N., A.C.T.N., R.J.v.B., C.J.W.B., M.J.S., J.J.B.), Leiden University Medical Center, Leiden, The Netherlands; and the Department of Cardiology (M.B., G.B.), University of Bologna, Bologna, Italy.

Abstract

Background— Left ventricular (LV) fibrosis is important for the response to cardiac resynchronization therapy (CRT). Calibrated integrated backscatter derived by 2D echocardiography quantifies myocardial ultrasound reflectivity, which may provide a surrogate of LV fibrosis. The aim of the study was first, to investigate the relation of myocardial ultrasound reflectivity assessed with calibrated integrated backscatter on CRT response, and second, to explore the “myocardial ultrasound reflectivity–CRT response” relation in patients with ischemic and nonischemic heart failure (HF). Methods and Results— One hundred fifty-nine patients with HF referred for CRT underwent an extensive echocardiographic evaluation at baseline and at 6-month follow-up. LV dyssynchrony was derived from speckle-tracking analysis. Calibrated integrated backscatter was obtained from the parasternal long-axis view. The mean value of calibrated integrated backscatter of the anteroseptal and posterior wall was used to estimate myocardial ultrasound reflectivity. CRT response was defined as reduction ≥15% of LV end-systolic volume. At baseline, LV dyssynchrony was significantly larger in responders as compared with nonresponders (188�96 ms versus 115�68 ms, P <0.001), and CRT responders showed less myocardial ultrasound reflectivity as compared with nonresponders (−20.8�3.0 dB versus −17.0�3.0 dB, P <0.001). In multivariable logistic regression analysis, independent predictors for CRT response were LV dyssynchrony, renal function, and myocardial ultrasound reflectivity. Importantly, myocardial ultrasound reflectivity provided an incremental value to CRT response (χ 2 change=40, P <0.001). Considering patients with ischemic HF, the only independent predictor of CRT response was myocardial ultrasound reflectivity, whereas in patients with nonischemic HF, independent predictors of LV reverse remodeling were myocardial ultrasound reflectivity, LV dyssynchrony, and renal function. Conclusions— Assessment of myocardial ultrasound reflectivity is important in the prediction of CRT response in ischemic and nonischemic patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3